sciscape Publications
← All publications

A joint SEEG rank check gave a positive adjusted change in six of eight sessions after contact order reversal at 20 to 500 ms

We tested a joint waveform rank check in eight public STReEF SEEG sessions. The fixed subset had 96 conditions. Three early pulses formed the reference. The check flagged 176 of 480 reverse-order pulses (36.7 percent) and 43 of 192 held-out same-order pulses (22.4 percent). After subtraction of the before-pulse control, the equal-person change was 11.5 percentage points. The descriptive 95 percent person bootstrap interval was 1.6 to 20.8 points. The planned two-sided sign-flip p value was 0.0625. Six of eight adjusted changes were positive. Contact order and time changed together. The check missed most reverse-order pulses. These data do not establish a causal contact-order effect or online BCI benefit. The package preserves the protocol, exact pulse products, source versions, code, all rank outcomes, and two figures.

SEEG · electrical stimulation · conformal rank check · brain-computer interfaces · epilepsy · waveform analysis

Admitted 0 citing publications

References

6
  1. usesA scale fit from one pulse lowered mean SEEG forecast error in six of eight sessions after contact order reversal at 20 to 500 ms sci:sha256:18c6ed2417c8fa21e9a22c8580a0e0bf89683a8de79f7dbda88c0cbd316fe6c2

    This publication supplied the exact STReEF pulse products, fixed 96-condition subset, native audit traces, and pinned public source records.

  2. usesA joint rank check accepted 83.2 percent of later SEEG responses at 20 to 500 ms in eight patients after five calibration pulses sci:sha256:293b34e71ea8d2f99a69e38b3c7c5227f6549f67906ebb9986851394508c542b

    This publication supplied the symmetric joint rank score across SEEG readouts. The new test uses three calibration pulses and a before-pulse control at contact order reversal.

  3. usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee

    This publication supplied the metadata selection and raw range extraction code. The package preserves and checks these source methods.

  4. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The analysis used STReEF dataset ds005448 version 1.0.0; its saved dataset metadata records this exact version DOI and CC0 license.

  5. doi:10.1016/j.ynirp.2025.100274
  6. doi:10.1007/s12021-022-09567-6

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.