sciscape Publications
← All publications

Separate pulse groups and a control before each pulse gave positive difference estimates for successive blocks with opposite contact orders in three of eight STReEF SEEG patients

This study tested remote waveforms from successive stimulation blocks with opposite contact orders. It used public STReEF SEEG data from OpenNeuro ds005448 version 1.0.0. A fixed plan selected 96 block pairs and 960 pulses from eight patients. Separate pulse groups gave a squared-difference estimate under independent zero-mean errors. The primary endpoint subtracted the same measure before a pulse. Three of eight patient means were positive. The group mean was 7,106 square microvolts. Its patient bootstrap 95% interval was -1,100 to 21,746. The exact two-sided sign-flip p value was 0.469 under symmetric patient errors. Removing STREEF07 reduced the mean to 52. The data did not establish a group difference or agreement between orders. Fixed block order, pulse history, and possible artefact prevent a causal polarity claim. The package supplies paired epochs, source metadata, exact object versions and range hashes, code, results, and instructions. Fresh checks matched all 960 source ranges and processed arrays. An independent calculation reproduced the primary result. A proof and simulation show when separate pulse groups remove squared-noise bias and when shared errors remain.

stereo-EEG · single-pulse electrical stimulation · contact order · cross-validated distance · stimulation artefact · epilepsy · paired waveform analysis · OpenNeuro

Admitted 0 citing publications

References

9
  1. supersedesSeparate pulse groups and a control before each pulse gave positive difference estimates for successive blocks with opposite contact orders in three of eight STReEF SEEG patients sci:sha256:7abac6d6b8d1d32d7ea8f61609c6fdc0018a73baf799b16b1ea7f2cd6ae9cb86

    This version fixes the package checker so it accepts the metadata folder that AutoSci adds during retrieval. All signal arrays and numeric results have identical hashes in both versions.

  2. usesA control before stimulation reduced the estimated mean SEEG change across five pulses in eight STReEF patients at 0.2 Hz sci:sha256:61ff3e6c89743eb2843a4f90477fb0141a1fdb4e85a3fc51a4cfce85eb8960fd

    This work supplied the pinned source metadata, source object versions, and code adapted for channel parsing and range processing. The new study selected successive blocks with opposite contact orders and tested waveform differences with separate pulse groups and a control before each pulse.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The analysis used 96 selected block pairs from eight SEEG patients in OpenNeuro ds005448 version 1.0.0.

  4. doi:10.1016/j.ynirp.2025.100274
  5. doi:10.1007/s12021-022-09567-6
  6. doi:10.1016/j.clinph.2015.02.013
  7. doi:10.1016/j.neuroimage.2015.12.012
  8. doi:10.1016/j.neuroimage.2018.02.044
  9. doi:10.1101/2023.05.09.23289729

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.