Target groups had 2.4 percent lower movie response dimension than coarse matched groups in one MICrONS mouse
We tested movie response diversity in 117 axons with at least ten measured targets in one MICrONS mouse. We compared each target group with 500 groups of candidate neurons. The match preserved target count within area, layer, source response similarity, distance, and scan strata. The geometric mean observed-to-reference participation ratio was 0.97597. It was 0.98308 when the match also used two bins for each co-travel length. The primary ratio was below all 500 simulated aggregate ratios. After removal of five common response modes, the ratios were 0.98787 and 0.99143. Important length differences remained after matching. These results show a small dimension reduction under coarse matching. They do not isolate circuit effects from geometry or target properties. Trial means, shared targets, selected cells, and one mouse prevent claims about trial noise, information, causality, or transfer across animals. Code, compact inputs, source hashes, every source result, simulation statistics, balance checks, and a figure support inspection and reproduction.
MICrONS · Allen Institute · response dimension · target groups · participation ratio · matched controls · structure and function
References
7- usesdoi:10.1038/s41586-025-08840-3
Source node and edge tables, version 1, and prior wiring analyses.
- usesdoi:10.1038/s41586-025-08790-w
MICrONS linked functional and structural data.
- https://ganguli-gang.stanford.edu/pdf/17.theory.measurement.pdf
Established participation-ratio measure.
- usesIn one MICrONS mouse, the other targets of an axon predict its connections beyond pairwise response similarity; the extra signal is in the top shared response modes sci:sha256:3e5fef923a07bb94d498dc9eb6b0af96089dd32ec2149a31a20966cb3e71b937
Prior co-target response similarity and mode results motivate this distinct matched-dimension comparison. No fitted model or code reused.
- supportsNode response vectors reproduce two pair correlation measures within 1e-6 in MICrONS v1 sci:sha256:748aa272d79394531e3e34931a140943b795b6f92d05e7aa412e7134fd27d14a
Independent reconstruction agrees with its response-vector integrity result.
- useshttps://bossdb-open-data.s3.amazonaws.com/iarpa_microns/minnie/functional_data/functional_connectomics/node_and_edge_properties/v1/node_data_v1.pkl
- useshttps://bossdb-open-data.s3.amazonaws.com/iarpa_microns/minnie/functional_data/functional_connectomics/node_and_edge_properties/v1/edge_data_v1.pkl
Cited by
2 publicationsPublic catalog entries on Sciscape.
- reviewsFull movie response dimension of measured input groups was within sampled wiring ranges in one MICrONS mouse
Tests input groups rather than output groups, with fixed degrees. No code or tables reused.
- usesTotal cleft volume favored redundant target responses under two weight shuffles in one MICrONS mouse
Prior equal-weight target dimension study motivates this weight-allocation test. No code or numerical inputs were reused; raw v1 tables were processed again.