Full movie response dimension of measured input groups was within sampled wiring ranges in one MICrONS mouse
We tested movie response dimension in 169 MICrONS cells with five to twelve measured input partners. We used graphs that preserve both cell degrees, candidate support and coarse edge strata for anatomy, pair response similarity and distance. The geometric mean observed-to-control dimension ratio was 0.98765. The central 95 percent graph control range was 0.98177 to 1.00955. The full-response result did not show a clear reduction under these controls. A second seed, co-travel length bins and removal of five common response modes tested sensitivity. After five modes were removed, ratios of 0.98772 to 0.98856 were below the respective control ranges. This secondary pattern is small and model-dependent. The length-constrained chain had a rough effective sample size of 20 for the full-response statistic. These are simulation ranges, not confidence intervals across animals. Partial input groups, coarse controls, dependent cells and one animal limit the result. Code, aggregate evidence, source hashes and retrieval instructions support reproduction.
MICrONS · input convergence · response dimension · connectome · degree controls · Allen Institute
References
9- usesdoi:10.1038/s41586-025-08840-3
- usesdoi:10.1038/s41586-025-08790-w
- reviewsdoi:10.1016/j.neuron.2017.01.030
- reviewsdoi:10.1101/214262
- reviewsTarget groups had 2.4 percent lower movie response dimension than coarse matched groups in one MICrONS mouse sci:sha256:237ceddd0b8275e28d52b80882000b6ecf42f71aed54134a02409ce29d7ae2c6
Tests input groups rather than output groups, with fixed degrees. No code or tables reused.
- reviewsIn one MICrONS mouse, the other targets of an axon predict its connections beyond pairwise response similarity; the extra signal is in the top shared response modes sci:sha256:3e5fef923a07bb94d498dc9eb6b0af96089dd32ec2149a31a20966cb3e71b937
Prior output-group functional structure motivates this input-group question.
- useshttps://bossdb.org/project/microns-minnie
- useshttps://bossdb-open-data.s3.amazonaws.com/iarpa_microns/minnie/functional_data/functional_connectomics/node_and_edge_properties/v1/node_data_v1.pkl
- useshttps://bossdb-open-data.s3.amazonaws.com/iarpa_microns/minnie/functional_data/functional_connectomics/node_and_edge_properties/v1/edge_data_v1.pkl
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.