Full-session calibration gave no clear mean error reduction for five-pulse SEEG forecasts at 20–500 ms in eight patients

Calibration from other sites gave no clear mean error reduction over one full waveform scale. The test used OpenNeuro ds004696 version 1.0.1, with eight epilepsy patients, 86 sites, and 886 site-readout pairs. Each target forecast used five early pulses and was tested on five later pulses at 20 to 500 ms. Four fixed cosine groups had separate scale estimates. A convex rule combined these estimates with the full scale. The blend fraction used only early pulses at other sites in the same patient. The target site was excluded from that fit. The rule assumes full-session calibration. The mean patient error reduction was -0.086%. The descriptive 95% patient interval was -0.367% to +0.117%. Four of eight patients improved. The exact patient sign-flip reference value was p = 0.742. The package preserves an exact calibration rule, compact inputs, source hashes, fitted parameters, pulse errors, figures, and replay checks. The result concerns processed voltage in one session per patient. It does not establish online control or equal method performance.

SEEG · electrical stimulation · forecasting · calibration · signal processing · error reduction · cosine transform

Admitted 1 citing publication

References

7
  1. usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a

    This work defined the full waveform scale used as the main comparator and as one end of the new blend.

  2. usesCutoff selection from five pulses increased mean 20–500 ms SEEG forecast error relative to full waveform scaling in eight patients sci:sha256:4e2122ca334a5cb7443cd19dc5cf392aebe4e5dbd23bea4d81292273bc91ca67

    This archive supplied all fixed input arrays, row tables, source pins, and the extraction recipe. The new test adds a convex blend fitted at other sites.

  3. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    This work supplied the eligible same-block bipolar SEEG cohort and the first-five/final-five pulse split. All 886 eligible rows were retained.

  4. Four fixed temporal scales increased mean 20–500 ms centered bipolar SEEG forecast error relative to one scale in eight patient sessions with five calibration pulses sci:sha256:2849ada547521a473f275ebeec96b85d452cc6cfbda4c7e0b39e4e786e562f68

    [Legacy relation: reproduces] The fixed four-scale comparator reproduced the mean error increase of 0.480859% on the same cohort and products. This is numerical reproduction, not a new cohort replication.

  5. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis used individual pulse voltages from OpenNeuro ds004696 version 1.0.1; the source commit and file hashes are recorded in the package.

  6. doi:10.1523/JNEUROSCI.2201-22.2023
  7. doi:10.1371/journal.pcbi.1011105