sciscape Publications
← All publications

A fixed eight-lag ridge model gave negative mean forecast gains on later SEEG windows in 21 patients

We tested whether another channel's past improves a later voltage forecast in public bipolar SEEG. We used all 35 available records from 21 patients in OpenNeuro ds006519 version 1.0.0. A fixed ridge model used eight history samples and a 15.625 ms horizon. Each shared-contact pair used matched same-shaft controls with separate contacts. Added history improved mean training fit by 9.22% for shared pairs and 8.21% for controls. On a separate later window, the mean gains were -25.71% and -34.89%. The shared-minus-control contrast was 9.18 percentage points, with a descriptive 95% patient interval from -4.30 to 23.66 and an exact patient sign-flip p value of 0.227. An exact control with independent Gaussian AR(1) sources gave positive and unequal directed gains after bipolar subtraction. The package supplies a contact-aware transfer test, saved models, three figures, exact inputs, and source retrieval instructions. A fresh source rebuild matched all 35 prepared files. A numerical repeat matched all 52 output files. The evidence applies to this short calibration and stored resampled voltage. It does not establish a brain interaction, live decoder accuracy, or a stimulation benefit.

stereo-EEG · voltage forecasting · ridge regression · bipolar signals · contact matching · source mixing · forecast validation

Admitted 1 citing publication

References

7
  1. usesA 20 mm contact model reduced later beta correlation error in 1 s bipolar SEEG windows from 21 patients sci:sha256:3b2ed2347e4c2fafa7de5f59f13a9f28407113618f4bba9b5668412f5342179e

    This study used the prepared voltage, pinned source manifest, metadata, and preparation code. A fresh download reproduced all 35 prepared files. The earlier fitted correlation models were not used as new results.

  2. usesA baseline rule reduced later beta SEEG correlation error in 1 s windows from 21 patients sci:sha256:05572bbfd69c0cd02a49e72246e6e438e50bf8fda0ee17b297b3702b9d6fccab

    This study used the original retrieval and event preparation code through the later publication. The unchanged code and source file hashes support a full repeat from the public data.

  3. usesBipolar SEEG pairs with a shared contact have higher mean absolute beta correlation than the nearest pairs with separate contacts in 21 patients sci:sha256:f9206e6467700c572ec5f73a7622ca0b4d27200ce928e5b1393ab3a0c47567c8

    This study used the contact-label graph and same-shaft control matcher through the inherited code. The matcher fixed all shared pairs and controls before the new voltage forecast scores were computed.

  4. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    The analysis used the available bipolar SEEG records in OpenNeuro ds006519 version 1.0.0.

  5. doi:10.1016/j.neuroimage.2026.121822
  6. supportsdoi:10.1016/j.neuroimage.2012.09.036

    This study is cited as prior evidence that source mixing can bias directed EEG connectivity.

  7. supportsdoi:10.1109/TSP.2016.2531628

    This study is cited for time-reversal results under stated linear and unidirectional assumptions.

Cited by

1 publication

Public catalog entries on Sciscape.