A 20 mm contact model reduced later beta correlation error in 1 s bipolar SEEG windows from 21 patients
We tested a fixed contact model for later beta correlation forecasts. We used all 35 public records from 21 patients in OpenNeuro ds006519, version 1.0.0. The main model had a 20 mm spatial scale. Two early 1 s windows fitted the weights. Two later 1 s windows supplied the test correlations at 13 to 30 Hz. Scored channel pairs had separate physical contacts. Each patient had equal weight. Mean squared error was 0.038353 for shrinkage toward zero and 0.038090 for shrinkage toward geometry. The paired reduction was 0.000263, or 0.69 percent of mean comparator error. Its descriptive 95 percent patient bootstrap interval was 0.000170 to 0.000355. Twenty patients had lower error. The gain was larger on nearby pairs. The check on different electrode shafts did not establish a gain. Permuted contact locations did not reproduce the improvement. The package adds a full matrix forecast tool and preserves signals, contact locations, predictions, code, three figures, source hashes, and reproduction instructions. All 355 source files passed fresh size and hash checks. A complete rebuild matched all 35 prepared records exactly. A repeat matched all 42 numerical files byte for byte. These exploratory results apply to offline voltage statistics in a reused epilepsy cohort. Brain-interface task accuracy and causal stimulation effects were not tested.
stereoelectroencephalography · SEEG · beta band · correlation forecasting · contact geometry · spatial covariance · shrinkage · epilepsy · brain-computer interfaces
References
4- usesA baseline rule reduced later beta SEEG correlation error in 1 s windows from 21 patients sci:sha256:05572bbfd69c0cd02a49e72246e6e438e50bf8fda0ee17b297b3702b9d6fccab
We used its event arrays, source manifest, source reader, filter code, and zero-target forecast rule. A fresh complete source rebuild matched every prepared array. The new study tests a fixed contact geometry target on the same later signals.
- usesBipolar SEEG pairs with a shared contact have higher mean absolute beta correlation than the nearest pairs with separate contacts in 21 patients sci:sha256:f9206e6467700c572ec5f73a7622ca0b4d27200ce928e5b1393ab3a0c47567c8
We used its contact parsing and overlap masks through the scalar forecast package. These masks exclude pairs that share physical contacts. Its audit motivated retention of bipolar contact signs in the geometry model.
- usesdoi:10.18112/openneuro.ds006519.v1.0.0
This exact public release supplied the signal and contact data analyzed in the 35-record study.
- supportsdoi:10.1016/j.neuroimage.2026.121822
The source article supplies the wider-study context and reported clinical sample size referenced in the text.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesA fixed eight-lag ridge model gave negative mean forecast gains on later SEEG windows in 21 patients
This study used the prepared voltage, pinned source manifest, metadata, and preparation code. A fresh download reproduced all 35 prepared files. The earlier fitted correlation models were not used as new results.
- usesA fixed 30 mm test of 1 s SEEG windows did not establish greater repeated beta correlation change near motor stimulation in 15 patients
We used its pinned source manifest, source metadata, retrieval code, contact parser, and BrainVision reader. A fresh source download and release checkout verified all inputs. This study adds a spatial test of repeated beta correlation change at native sample rates.
- usesA fitted model of independent contacts increased mean later beta correlation error for shared-contact SEEG pairs in one-second windows from 21 patients
We used its account of a contact distance model to choose a distinct model question. This study fits independent contact variances and scores pairs with a shared contact. We did not use its code or data arrays.