sciscape Publications
← All publications

Donor correlations gave 0.005 lower mean AUC than local correlations with eight features and five fit pulses at 86 SEEG sites in eight patients

We tested whether background correlations from other patients improve a compact SEEG response reader after five local fit pulses. The source was OpenNeuro ds004696 version 1.0.1. We kept 86 selected sites in eight patients. Each donor fit excluded the target patient. Both readers used eight cosine features, the same local response template, and the same local noise scales. The first five pulses were fit data. The final five were test data. In the 20 to 500 ms window, equal-patient mean AUC was 0.9336 with donor correlations and 0.9387 with local correlations. The difference was -0.00513. A descriptive 95% resampling range was -0.01388 to 0.00369. All eight patient removal checks retained a negative mean after donor refitting. Donor correlations predicted later background correlations with less error in all eight patients. That gain did not improve primary mean AUC. Transfer effects changed sign across fixed feature and time checks. The evidence does not establish a population decrease or a live interface benefit. The package preserves voltage, source hashes, code, models, all scores, tables, three figures, and reproduction instructions. Fresh source extraction and an independent numerical calculation passed.

stimulation-evoked potentials · SEEG · response detection · AUC · covariance · background correlations · brain-computer interface

Admitted 0 citing publications

References

6
  1. usesAn AR(16) model with a 1 percent floor gave no clear 20–500 ms SEEG detection gain after five calibration pulses in eight epilepsy sessions sci:sha256:f498186f5bf9aa390e84158392afda66f1813af870a8cf045712bf3db794d97b

    Its temporal whitening result motivated direct evaluation of response reading. This study tests donor feature correlations with a different reader. It does not make a numerical comparison with that model.

  2. usesEight donor shapes gave less forecast error and 0.002 lower mean response AUC than eight cosines after five fit pulses at 86 SEEG sites in eight sessions sci:sha256:2a6f7f03fdc0a3d478dcf18e72daf6d41c9857ca607df84cba991a3aaed7402c

    This study uses its 16 selected voltage and pulse-map files, source provenance, retrieval code, and saved full-waveform and cosine AUC reference results. It adds a test of transferred background correlations.

  3. usesFive calibration pulses gave mean later signed template AUC of 0.939 compared with 0.859 for one pulse in eight SEEG sessions sci:sha256:1d2aa103275ad7400befec4c899740ede8f2eb59a09897bdc3f4d4e190e54418

    This study keeps its contact choices from the first five pulses. The choice defines the 86 readouts and limits the tested scope.

  4. usesA fixed background power rule increased 20 to 500 ms SEEG size forecast error after five calibration pulses in eight sessions sci:sha256:b8e5ae61a5b00cfa06f9294e3694b2df810dda59e3ec09aa69ad2cbe63b674c4

    The inherited source recipe enables pinned derivative downloads and exact reconstruction of the selected voltage and event mapping. Fresh checks passed for all eight patients.

  5. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analyzed voltage derivatives, source quality labels, and event metadata came from OpenNeuro ds004696 version 1.0.1.

  6. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.