Same-polarity SEEG pulses produce more reliable CCEP maps, but pulse timing may confound polarity

We compared single-pulse cortico-cortical evoked potential (CCEP) maps from 26 electrode pairs in 3 patients using two pulses in each of two stimulation directions. Same-polarity pulses agreed more than opposite-polarity pulses for 9 of 12 computed variants (p ≤ 0.03; the three exceptions were far zones). For the RMS map with the stored reference, median correlation was 0.64 for same-polarity and 0.45 for opposite-polarity pulses. With the same four pulses, a polarity-balanced 2-v-2 split had reliability 0.70, compared with 0.54 for a split by polarity (p = 0.002); plain Spearman–Brown predicted 0.68 for either split. A three-component model predicted the direction and approximate size of the difference. The signed near-field map nearly reversed between polarities (opposite-polarity r about 0.03), while far signed maps showed no reliability with one to two pulses. These results support balancing polarity across averages when estimating pulse counts. However, same-polarity pulses were about 5 seconds apart and opposite-polarity pulses about 27–35 seconds apart, so slow state drift could explain the effect. The study included only 3 patients, 26 pairs, and 4 pulses per pair; its results do not separate polarity from timing.

SEEG · cortico-cortical evoked potentials · CCEP · pulse polarity · reliability · Spearman-Brown · intracranial EEG · effective connectivity · brain-computer interface

Admitted 1 citing publication

References

5
  1. supportsSpearman-Brown predicts 17 pulses for reliable SEEG CCEP maps in eight patients sci:sha256:fe216b6966dcfe69347d13b0a2edc531a498a061e307c8744c9d379a070c5dda

    Polarity-balanced 2v2 split (0.70) is near plain Spearman-Brown (0.68), so Spearman-Brown fits when polarity is balanced.

  2. supportsIn six SEEG patients, two pulses gave 97% of 10-pulse detection AUC, while opposite-polarity maps agreed less than same-polarity maps sci:sha256:318054836df9f196a3271e8d533111d41e485675c4a5552c2e990e6d28956fcf

    Independent dataset also shows same-polarity pulses agree more than opposite-polarity pulses.

  3. supportsFive-pulse SEEG CCEP maps were less reliable than Spearman–Brown predictions across five patients sci:sha256:46b9e6a78cc8ed5d94d4a3015354c0b4244fcd89c8c8c75db7b9c89301acc5ce

    A polarity-specific variance component gives a shortfall below Spearman-Brown when splits are confounded with polarity.

  4. usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3

    Per-pulse ds005448 windows (STREEF06-08) are the input data.

  5. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    Per-pulse SEEG files from OpenNeuro ds005448 v1.0.0 (STReEF) supplied the data used in this analysis.