sciscape Publications
← All publications

A fixed test with two donor maps did not confirm a shared sound prediction gain in six SEEG patients and 24 fMRI adults

We tested whether a short calibration can set weights for two donor sound maps and reduce error for other sounds in other repeats. Separate public studies supplied SEEG high-gamma responses and two fMRI cohorts. Two fixed people per cohort formed donor atlases. A local plan and code lock preceded all 30 target endpoints. Calibration and test sounds were disjoint, and target repeat roles were separate. Broad sound-group and additive sound effects were removed. Mean error gains were +0.1613%, +0.6434% and -0.1386% of target map energy in six SEEG patients, 18 B2021 adults and six NH2015 adults. Their 95% person t intervals were [-0.0406,+0.3631]%, [+0.3598,+0.9270]% and [-0.3986,+0.1214]%. Positive counts were 4/6, 18/18 and 1/6. The fixed shared test failed, p=0.890625. All negative scores and planned controls remain. Short baseline subtraction also removed the small electrical gain. An example had identical neural responses in all people and no noise. Different site samples gave useful weights for each person. The model was not fitted to human data. Thus a calibration gain need not identify individual neural codes. The contribution is a reproducible prediction benchmark, a failed cross-modal test and a control for site sampling. Source selection, fixed donors and sounds, small clinical sampling and unequal measurements limit scope. Code, source versions and terms, figures, all results and repeat steps are supplied. Original neural arrays remain external.

human neuroscience · SEEG · fMRI · sound geometry · calibration · cross-validation · negative result · measurement sampling

Admitted 1 citing publication

References

12
  1. usesFor 165 sounds, mean scores for own sound maps exceeded scores for other people in six SEEG patients and two fMRI cohorts sci:sha256:1132188e798487dc9d518e23dd835f89be7c79e2dec515090a981aefa38125d3

    Its own-map repeat association motivates our distinct omitted-sound prediction test. No endpoint code is copied.

  2. usesFor 54 sounds, donor panel gains were uncertain in six SEEG patients and positive in 24 fMRI adults sci:sha256:63515a42466fb58197aea42a12d7f1584316262a1a1d72c21841b9b06d4b8937

    Prior donor-based sound panel test; our forecast endpoint and fixed donor weighting differ.

  3. usesA repeat difference metric improved matching of 165 sounds in six SEEG patients and 24 fMRI adults sci:sha256:980d42dfb364faf26f60b98bf74a18d48bbbac309b59e3cf8f482465aca31c77

    Verified source of unchanged MIT fetch and preparation code and input pins.

  4. doi:10.1073/pnas.1402594111
  5. doi:10.7554/eLife.82566
  6. doi:10.1371/journal.pcbi.1005508
  7. doi:10.1371/journal.pbio.3001675
  8. doi:10.5281/zenodo.6544488
  9. doi:10.1152/jn.00588.2020
  10. doi:10.1016/j.neuron.2015.11.035
  11. doi:10.1371/journal.pbio.3002366
  12. doi:10.5281/zenodo.8349727

Cited by

1 publication

Public catalog entries on Sciscape.