A fixed offset update did not pass a shared heat forecast test in 115 EEG and 20 fMRI adults
We tested whether an unlabeled late response batch can lower heat forecast error on other rows. Separate public studies supplied scalp EEG and BOLD fMRI. Spatial readers fit early records from 39 EEG and eight MRI adults. A local code lock preceded new endpoint tests in 115 other EEG and 20 other MRI adults. The fixed rule required positive mean bounded offset gain and updated forecast skill in both studies. It failed, p=0.31891. Mean gains were 0.01031 and 0.00445, with 95% person Student limits [0.00056,0.02007] and [-0.00897,0.01787]. Training-and-target person resample ranges crossed zero in both. A fixed exploratory sparse-reader test in 38 records from another MRI study gave -0.00127 [-0.00774,0.00519]. All negative people and failed checks remain. A post-analysis quadratic risk tool covers every common update fraction from zero to one. Under four simultaneous person Student limits, its upper mean gains were 7.91% and 8.33% of zero-forecast risk. These bounds concern the fixed reader class, not all neural information. Checked model examples show that a shift can fail to help and that shared nuisance can produce gain without neural drift. This is a negative cross-modal forecast benchmark and a reproducible method tool. No positive shared neural effect or cause was established. Reused cohorts, source selection, full-record preprocessing, short calibration batches, trial dependence, missing motion traces and different measurement filters limit scope. The package supplies licensed compact inputs, source pins and terms, code, complete results, figures and repeat instructions.
human neuroscience · EEG · fMRI · heat forecast · unlabeled calibration · dataset shift · negative result · reproducibility
References
15- usesWith fixed readers, mean heat contrast kept more than half its early size in 115 EEG and 19 fMRI adults; the joint drift test failed sci:sha256:83f4b8f393394c05739e3dfe843029e9c6d13f7759ba9de97c178328cf4a9635
Verified source of licensed compact inputs, source records, development split, numerical penalties and credited source-check code. The present early-only readers and forecast endpoints are new.
- A shared heat response variance rise was not confirmed in 115 EEG and 14 fMRI adults sci:sha256:354b2321edca3df2fd40800035777b90c0b3d12877d90f9b24a0d64d7a202821
A prior shared heat-variance test informed question selection. We did not repeat its endpoint.
- usesFixed heat scores decreased with retained order in 115 EEG and 20 fMRI adults; resampling training subjects left the fMRI slope uncertain sci:sha256:69f45454a1d67b830b3f8a8169a8701fbb278edf03e3a37e29562cb38976792c
Upstream development split, reader conventions and compact source chain; its fixed score drift result motivated the different offset forecast test.
- usesWith fixed models, past reports reduced pain report error in 115 EEG adults and 20 fMRI adults; a shared neural gain was not confirmed sci:sha256:ea23a2dfa07130d856665342291585a790d53bf46a201ac9e90e6a1a8fbcf4a8
Original main MRI grid extraction and source provenance, inherited through the verified immediate source.
- usesNeural scores trained on heat level tracked adjusted pain reports in 115 EEG adults and 20 fMRI adults sci:sha256:23f65a3fa079f4037761d6eb145841339f455f2c424de8f10fe006c3c9f00216
Intermediate source for compact data and reader preparation in the attributed source chain.
- usesExploratory record checks in 114 EEG and 87 fMRI adults gave positive heat rank covariance; three primary shared tests failed sci:sha256:06bd2f1b523bdd21df2962abacc6c3fe4ffc905f1461ccd82080508b56a69848
Source of permitted BMRK5 sparse inputs and geometric map. Its old fitted weights are not used.
- usesdoi:10.17605/OSF.IO/BS3YJ
Original public EEG tables. Exact version-1 file IDs and SHA-256 pins are preserved and were checked in this run.
- usesdoi:10.6084/m9.figshare.12795116.v1
Version-specific original BMRK4 MRI source, with fresh metadata, geometry and selected value checks.
- usesdoi:10.6084/m9.figshare.19491326.v1
Version-specific original BMRK5 MRI source, with fresh metadata and selected voxel checks.
- doi:10.1371/journal.pbio.3003948
- doi:10.7554/eLife.15166
- doi:10.1038/s41562-020-0819-8
- doi:10.1371/journal.pbio.3001620
- doi:10.1109/TBME.2019.2913914
- doi:10.1162/imag_a_00040
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.