A refitted interval included zero for high gamma gain over contact number under patient holdout in 33 SEEG patients
We tested whether high gamma power adds seizure onset label ranking value beyond contact number within inferred electrode shafts. We used two public one-minute samples per patient from OpenNeuro ds004100, version 1.1.3. We fixed the model before fitting. Each test patient was excluded from all training. Mean within-shaft AUC was 0.782 for contact number and 0.794 for the combined model. The mean change was 0.013. A patient bootstrap refitted all models in 1,999 draws. Its 95 percent interval was -0.018 to 0.079 and included zero. The test does not establish added value for this fixed model. It does not prove that high gamma has no added value. The package preserves features, folds, scores, bootstrap draws, code, and pinned data retrieval instructions. Independent checks use fresh public signals. The scope is clinical label ranking in 33 selected SEEG patients, with independent patients assumed for the interval.
stereoelectroencephalography · SEEG · high gamma power · contact number · seizure onset labels · patient holdout · AUC · patient bootstrap
References
5- usesLower contact numbers gave mean seizure onset AUC 0.794 within mixed inferred shafts in 34 selected ds004100 SEEG patients sci:sha256:50d777142ef4ebc45c41203ba318cb2244c6b807e8d402b44d8ba5067784feec
Its contact number result motivated the location baseline. We did not use its numerical outputs. We formed the current features from the source covariance package.
- usessci:sha256:ad80bc2bd0737883d3eb45a01e266fee6a996e9e1e541f80de6ada0bdd0447e5 not known to Sciscape
We used its pinned metadata, retrieval code, and 70 band covariance files. We checked all copied hashes and recalculated power from fresh public signals. Its labels and covariance inputs support the new patient holdout test.
- usesMean high gamma AUC within inferred shafts exceeds a label control in one-minute SEEG samples with an average reference from 33 HUP patients sci:sha256:46a12570ac1f98c21c7f72a6958c443edd3986f81154a8c30cc11c1f760e42a9
Its within-shaft gamma test motivated the added-value question. We did not use its numerical outputs. The current study tests a fitted combination with each test patient excluded.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Version 1.1.3 of the HUP iEEG Epilepsy Dataset supplied the clinical labels and signal source used for this secondary analysis.
- doi:10.1088/1741-2552%2Fac90ed
Background evidence on spatial bias in intracranial EEG motivates a contact-location baseline; it does not establish this study’s power-test result.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesEarly gamma change increased mean onset mark AUC when fixed models excluded each of 32 SEEG patients
Its related interictal high gamma result supplied context for the scope of patient exclusion and refitted uncertainty. Different bands, contact sets, references, and models prevent a band-specific comparison. We did not use its code, feature arrays, or fitted values.