Tests did not confirm shared visual repetition bounds in three EEG, 15 MEG and 18 fMRI records from two studies
We tested whether visual repetition changes a category response beyond one gain and keeps over half its initial pattern projection. Public data supplied EEG and MEG from one cohort and grating fMRI from a separate study. Four electrical-source people supplied development. A local lock preceded reserved scores. Fixed artifact and run-count rules retained three of 15 EEG candidates and all 15 MEG candidates. All 18 MRI arrays were included. The compact MRI file lacked run links. We kept each person’s lowest score over all 35 balanced subrun partitions. The mean half-retention differences were +0.001754 in EEG, +0.005376 in MEG and -0.041050 for the MRI lower bound. Pointwise 95% person Student limits were [-0.054077,+0.057585], [-0.007606,+0.018358] and [-0.089787,+0.007687]. All three shared claims failed Holm correction, p=1. An assumed chronological MRI link gave +0.068885 [+0.036798,+0.100971]. This conditional positive result does not replace the failed bound. The study supplies a negative benchmark and a tool for conservative inference with missing run links. It does not confirm absent neural coding or a positive cross-modal biological effect. Stable run means, independent errors, correct source labels and a suitable person mean model remain assumptions. Small EEG inclusion, shared electrical-source artifacts, distinct tasks and cohorts, inherited processing and vascular filtering limit scope. Code, source pins and terms, all outcomes, figures, audits and repeat steps are supplied. Original neural arrays remain external.
visual repetition · EEG · MEG · fMRI · projection retention · missing run links · response geometry · negative benchmark
References
8- usesdoi:10.1038/sdata.2015.1
Original electrical recordings and source task.
- usesdoi:10.17605/OSF.IO/P2K97
Pinned version-1 compact EEG and MEG epochs.
- usesdoi:10.3389/fnins.2018.00368
Compact data preparation and prior analyses.
- usesdoi:10.1038/s41467-018-05957-0
Pinned version-1 grating fMRI matrices and source protocol.
- doi:10.1038/s41467-020-18315-w
- doi:10.7554/eLife.82566
- usesWith stable means and independent repeat errors, mean finger response area was positive in five ECoG patients and six fMRI adults after feature mean removal sci:sha256:c293e29d52d8957ad7829a7235f89165da8ef76f78c8e034b10849250c73db0d
Four-repeat area principle and limits; no source code copied.
- usesWith fixed readers, mean heat contrast kept more than half its early size in 115 EEG and 19 fMRI adults; the joint drift test failed sci:sha256:83f4b8f393394c05739e3dfe843029e9c6d13f7759ba9de97c178328cf4a9635
Related fixed half-retention criterion; new task and source data here.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.