A fixed test did not confirm greater thumb contrast energy in two ECoG patients and six fMRI adults
We compared thumb contrast energy with mean energy per contrast among the other four fingers. Separate public human studies supplied high-frequency ECoG power and M1 fMRI patterns. A local plan preceded new endpoint scores. Development used two patients and one MRI adult. The fixed four-trial cell rule kept only two of six reserved patients, but all six reserved MRI adults. An exact count model predicts 2.03 calibration passes under uniform cue order. Two passed. Mean thumb-minus-nonthumb scores were 0.102757 and 0.099706. Their pointwise 95% person Student intervals were [-0.822965,1.028479] and [0.043266,0.156146]. The shared rule also required positive thumb energy in both modalities. It failed, intersection p=0.196317. An added two-trial rule kept all six patients. Their mean difference was 0.476392 [0.014975,0.937809], with six positive people. This was exploratory after the primary result. The four newly included patients had interval [-0.010119,1.336538]. All ten simultaneous added-check intervals included zero. Movement adjustment and feature-mean retention weakened the added scores. Negative energies remain. Independent contrast, distance and raw Fourier calculations checked the arithmetic. Exact models show that one response axis or shared errors can give a positive score. The package preserves source versions and terms, code, all results, figures and repeat steps. Source arrays stay external. This is a failed fixed test and a count-sensitivity benchmark. It does not confirm cross-modal generalization or causality.
human neuroscience · ECoG · fMRI · finger representation · thumb · representational geometry · calibration · negative result
References
11- usesWith stable means and independent repeat errors, mean finger response area was positive in five ECoG patients and six fMRI adults after feature mean removal sci:sha256:c293e29d52d8957ad7829a7235f89165da8ef76f78c8e034b10849250c73db0d
We reuse its public source pins, fetch code and window-local electrical feature reader. Its nonthumb area failure motivated the present contrast test.
- usesA five-finger order test with single-finger terms removed did not confirm a shared pattern in six ECoG patients and six fMRI adults sci:sha256:ea2439b63074400eda708748c2e755e5d8d627d22988dc85f0d2bf6782e860ff
Its fixed finger order test and exact score limits informed our narrower thumb question.
- usesA fixed test did not confirm shared finger pair structure in five ECoG patients and seven fMRI adults sci:sha256:d22893af7b32a68f335d0ab3987472b958c2c0f3e092f4ead3cb8847692089c4
It supplied upstream access code and a related failed adjusted geometry-transfer benchmark.
- usesFixed tests did not confirm four-axis finger gains in four ECoG patients and six fMRI adults sci:sha256:c7e2ab2de928e8ff187bbffb8ce92b6eb048152e30c642d36a4a8f65a3f86f64
Its upstream feature and source code is retained through SCI 7cba987e, with MIT notices.
- doi:10.1371/journal.pcbi.1002655
- doi:10.1038/s41562-019-0678-3
- doi:10.1038/nn.4038
- doi:10.1523/JNEUROSCI.0999-20.2020
- doi:10.1016/j.neuroimage.2014.07.002
- doi:10.1016/j.neuroimage.2017.08.051
- doi:10.1371/journal.pcbi.1005508
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.