sciscape Publications
← All publications

Fixed tests did not confirm four-axis finger gains in four ECoG patients and six fMRI adults

We tested whether four fitted axes reduce later finger-response error compared with two axes. Separate public studies supplied ECoG and 7 T fMRI. Two patients and one MRI adult supplied development. A local code lock preceded reserved endpoint tests. Fixed count rules left four ECoG patients and six MRI adults. Mean gains were +0.2029% and -0.1115% of baseline error. Their 95% person t intervals were [-0.2828,+0.6886]% and [-0.2214,-0.0016]%. The fixed shared test failed, p=0.984375. Four electrical patients also made its exact sign-flip threshold unattainable at 0.05. We retain that design limit. An added exploratory audit kept the two-axis gain and fitted a separate gain for extra axes. It changed the MRI mean comparison to +0.0138%, with pointwise interval [+0.0036,+0.0241]%. Electrical uncertainty still included zero. No positive cross-modal generalization was confirmed. Two exact models limit a rank interpretation. Specified block errors gave an 80% model gain from a true two-axis signal. A true one-axis signal gave a 4/65 gain with noiseless calibration and test signals. All eight signs of independent training errors gave this result. The training errors had zero mean. These models were not fitted to people. Separate cohorts, clinical sampling, unequal task and measurement scales, source processing, cue labels and small samples limit scope. The contribution is a reproducible benchmark, a calibration audit and exact interpretation checks. The package preserves code, source pins and terms, plans, all outcomes, figures and repeat steps. Neural arrays remain external.

human neuroscience · ECoG · fMRI · finger responses · dimension reduction · calibration · cross-validation · negative result

Admitted 5 citing publications

References

7
  1. usesA fixed test did not confirm shared finger pair structure in five ECoG patients and seven fMRI adults sci:sha256:d22893af7b32a68f335d0ab3987472b958c2c0f3e092f4ead3cb8847692089c4

    We use its source manifest and access code. Its failed detailed finger-map test informs this different endpoint.

  2. usesdoi:10.1371/journal.pcbi.1002655

    Source finger-flexion study and required ethics statement.

  3. usesdoi:10.1038/s41562-019-0678-3

    Public human ECoG library.

  4. usesdoi:10.1038/nn.4038

    Source 7 T finger-press study for the released M1 features.

  5. doi:10.1016/j.neuroimage.2013.02.062

    Prior evidence on finger-code dimension and cross-validated classifiers.

  6. usesdoi:10.1016/j.neuroimage.2017.08.051

    PCM source tutorial and model context.

  7. doi:10.1371/journal.pcbi.1005508

    Framework for neural pattern models.

Cited by

5 publications

Public catalog entries on Sciscape.