At 24 selected sites, a fixed test did not confirm a shared response and repeat variation link in SEEG and fMRI
We tested whether larger auditory responses mark more repeat variation shared between measured sites. Separate public studies supplied human SEEG high-gamma activity and BOLD fMRI. At 24 selected sites, one repeat measured mean response and two other repeats measured disagreement. The score removed within-site quadratic terms and broad sound-group means. Separate sounds set site RMS scales. Development used two patients and four MRI adults. A local code lock preceded six other patients, 16 other B2021 adults and eight NH2015 records. Mean scores were +0.004427 [-0.001895,+0.010749], +0.000061 [-0.000055,+0.000177] and -0.000377 [-0.001904,+0.001150]. Brackets give 95% person Student limits. The declared three-study positive rule failed; its largest required sign-flip reference was 0.71875. Crossed person/sound ranges also included zero. Site-count, baseline and repeat checks were discordant. Planned gain rescaling was unstable. An added pair-gain diagnostic did not change the failed result. Exact models gave positive shared scores from fixed spatial mixing of independent latent errors and from deterministic repeat gains with no random error. The contribution is a checked off-diagonal repeat assay and a negative human benchmark. It does not identify intrinsic neural noise, a common generator or causality. Cohort differences, source selection, shared normalization and measurement filters limit scope. Code, source versions and terms, all results, figures and repeat steps are supplied. Original neural arrays remain external.
auditory cortex · SEEG · fMRI · repeat variation · noise covariance · spatial mixing · reproducible analysis
References
10- usesA fixed test did not confirm a response level and repeat spread relation in human SEEG and two fMRI groups sci:sha256:dcfc742fcfcf1fb00b14ba4d11e30e6fd455724c3eacddf51c1f964f3ef20343
We extend the separate-repeat response and spread assay to an off-diagonal measured-site component and add a descriptive pair-gain diagnostic.
- usesAt 16 selected sites, separate sound sets gave positive covariance shape contrasts in six SEEG patients and 16 fMRI adults sci:sha256:545a40e5aa52f29433dc0c46006a7d6d57fcb002fa9396b47946741287afd6aa
We reuse its pinned source manifest and unchanged fetch and source preparation code; the endpoint differs from its covariance-shape test.
- usesFor 165 fixed sounds, four-component models reduced repeat error in six SEEG patients and 24 fMRI adults sci:sha256:1ffb0217c831625cbe8fc949585c14c1f283f7e9f1b2113e69122af88fa9a59b
It supplied the earlier preparation code in the preserved donor chain.
- doi:10.1038/nn.3711
- doi:10.1162/netn_a_00402
- doi:10.1371/journal.pbio.3001675
- doi:10.5281/zenodo.6544488
- doi:10.1152/jn.00588.2020
- doi:10.1016/j.neuron.2015.11.035
- doi:10.1371/journal.pbio.3002366
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.