Responses 1 and 4 gave 3.4% higher mean SEEG forecast error than responses 2 and 3 in five sessions at 20–500 ms
We tested which two recorded responses to use for stimulation-response calibration. We used OpenNeuro ds004457 version 1.0.2. At 138 sites in five patients, the first four accepted responses supplied calibration. Responses 1 and 4 formed a wider selection. Responses 2 and 3 formed an adjacent selection. Both estimates used two responses and were scored on 884 later responses at the same site and current. The main window was 20–500 ms. Each site error was scaled by its four-response calibration energy. The equal-patient mean error reduction from the wider selection was -3.44%, with a 95% patient bootstrap range of -9.02% to +3.23%. An exact mean-time match gave -4.05%. Recording pairs with no shared contacts gave +1.96%. These results do not establish a general spacing benefit or cost. The four-response reference had lower error than the adjacent estimate in all five patients. We verified 110 raw source files and rebuilt all input arrays and event tables exactly. Independent scalar scores and a full repeat analysis passed. The package contains a risk proof, three figures, voltage bins, forecasts and targets, tables, code, source hashes, and reproduction instructions. This reused-cohort study selects measurements from existing pulses. It does not test a change in delivered stimulation timing.
stimulation-response calibration · stereo-EEG · waveform forecast error · measurement selection · ventral temporal cortex
References
5- usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886
Uses the fixed ventral temporal contact list and base site-selection rules preserved in the direct input package. No fitted model is imported.
- usesAll earlier pulses gave lower mean SEEG forecast error than four recent pulses in five recordings at 20–500 ms sci:sha256:7572e2f1a54f04ee36ae5756aff12b06f8ed5349904c849467a91c2e6236dbe9
Uses the earlier count-versus-recency comparison to define a separate fixed-count question. Both new estimates use two responses. This citation supplies study context and no new data or score.
- usesFour pulse groups give an unbiased fixed SEEG map score under stable means and independent errors sci:sha256:437aed884bc5b4143245c229f4caab03cd7843c54486c5d39aebe814cc03791d
Uses the archived voltage bins, metadata, pinned source manifest, and extraction and selection code. All voltage inputs were rebuilt from the public raw files before this comparison.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analysis uses OpenNeuro ds004457 version 1.0.2; its version-specific DOI and CC0 license are recorded in the saved dataset metadata.
- supportsdoi:10.1523/JNEUROSCI.1325-22.2023
The cited source experiment provides the human ventral temporal single-pulse SEEG recordings described in this publication.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesFirst and final four-pulse SEEG means had a mean ratio of 1.071 against balanced splits in five sessions at 20 to 500 ms
Provides the related fixed-count pulse-spacing comparison in the same public cohort and a prior report of raw-source hash checks and exact bin reconstruction. It defines the nearby prior question. The current study measures first/final versus alternating splits of eight retained responses. Its raw reconstruction was not repeated here.