Recorded response timing reduced mean test error for beta power by 0.47% in selected pairs from eight SEEG recordings under fixed models
We tested whether recorded response times improve predictions of beta power on separate trials. We used OpenNeuro ds004473 version 1.0.2. The data came from eight people with epilepsy. Fixed rules retained 1,875 trials and 822 adjacent bipolar pairs. We compared a cue model with a model that added response timing. Pair choice and model fitting used training trials only. The mean reduction in test squared error was 0.47%. Its participant bootstrap 95% interval was -0.09% to 1.30%. Four of eight participants had lower error. The exact two-sided sign-flip p value was 0.3125. Recorded timing exceeded the mean shuffled-timing gain by 0.79 percentage points. That control kept pair choice fixed and assumed exchangeability within condition and fold. The planned all-pair model increased mean test error by 0.41%. Thus the primary models did not show a consistent gain across people. The result depended on the target and model rules. The package preserves new derived powers, all test predictions, source code, source versions, range hashes, raw samples, and reproduction instructions. Independent readers and calculations passed 221 checks. A second analysis reproduced all numerical outputs exactly. The source paper already reported sharper patterns after response alignment. This study adds a fixed prediction test in the same cohort. It does not isolate a causal movement process.
stereo-EEG · beta power · response timing · held-out prediction · ridge regression · OpenNeuro · permutation control
References
5- usesSelection of about 10 percent of bipolar pairs on 60 trials gave a mean adjusted beta gap of 0.47 dB in eight SEEG recordings sci:sha256:58f902ae4d39e155127bb1ba535ea1835434d7e43288b5e5fcd53880aa001967
Its estimate of pair-selection effects informed the rule that pair choice uses training trials only. Its powers and estimates did not enter our models.
- usesCommon-average and bipolar beta signs differ at 220 of 834 pairs in eight SEEG recordings sci:sha256:0d33b787e33457a21064797883180e8438973f90bf4411bf6f2bb853485c40e2
We reused its unchanged EDF range-reader code and source metadata, header hashes, object versions, and annex records. We extracted new powers for our own fixed windows and trials.
- usesBehavior synchronization samples match fixation in all 2,059 synchronized trials of OpenNeuro ds004473 version 1.0.2 sci:sha256:244746b16ad09014610f258b7c2b4badae2cedd0063ef2714fbe848df0b70aa1
Its audit showed that the synchronization sample points to Fixation. It also identified the sub-1 correctness conflict. We used explicit event samples and did not require the source correct flag.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
This publication analyzes OpenNeuro ds004473 version 1.0.2; the saved exact-version metadata identifies the dataset DOI and CC0 license.
- doi:10.1088/1741-2552%2Facae0a
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesAdded beta power gave minus 0.038 percent mean next-trial error reduction in eight SEEG patients under fixed ridge models
This study supplied the unchanged 38-window beta powers, trial and pair audits, source metadata, extractor, and range ledgers. We used them to test the next trial reaction time.
- usesBeta power increased from response levels at selected pairs in eight SEEG patients under independence and null sign symmetry
This work used the fixed beta power arrays, source reader, extraction code, source metadata, source object versions, and range hashes. They defined the input for separate-trial estimates.