sciscape Publications
← All publications

Median HFO duration gave no clear STE SOZ ranking gain beyond count and contact number in 18 SEEG sleep records

We tested whether median high-frequency oscillation (HFO) duration adds seizure onset zone (SOZ) ranking value above count and contact number. We used the first hour of 18 public SEEG sleep records and excluded each test patient from training. The main STE test used 1,285 channels and 23,297 events. Mean AUC changed from 0.7326 to 0.7292. The gain was -0.0034, with a 95% patient bootstrap interval of [-0.0246, 0.0102]. The fixed MNI check gave a gain of +0.0953, with interval [0.0253, 0.2170]. The MNI interval for comparisons on the same shaft included zero. Secondary intervals have no correction for the nine checks. These results concern released event marks and clinical SOZ labels. They do not establish surgical benefit. The package preserves exact source bytes, code, features, predictions, and all 11,000 bootstrap draws. A full repeat matched every numerical output.

high-frequency oscillations · seizure onset zone · stereoelectroencephalography · event duration · channel ranking · patient bootstrap · intracranial EEG

Admitted 3 citing publications

References

5
  1. uses20 ms HFO coincidence removal between shafts gave no clear SOZ rank gain in the first hour of 18 SEEG sleep records sci:sha256:52d7f41dbe867968ffe1622c76810af617f6d7482635ad3c69efc8880481c6f3

    This work supplied the compressed source event files, metadata, EDF headers, pinned retrieval manifest, retrieval code, and channel and repeat rules. Fresh public bytes were checked before the new duration analysis.

  2. usesThe interval for added STE HFO rank gain included zero in fixed contact order models for 17 SEEG patients sci:sha256:74196c384bfb7cfbe2317f8fd7c692d13fd50f2b78786436fee6371c62b31fc3

    This work informed the contact-number control and the secondary comparison of SOZ to other channels on the same named shaft. The current test adds event duration to fixed count and contact controls.

  3. usesHFO concentration in 1 s bins gave no clear SOZ rank gain over count on 1,285 channels in the first hour of 18 SEEG records sci:sha256:d3919c57fc8643409a319cb9f79cfb8f867b3bb607d3aaceb424d9c9506cfdd0

    This work informed the polynomial count control and the patient bootstrap design. Both models are refitted in each draw, with all copies of each test source patient excluded from training.

  4. usesdoi:10.18112/openneuro.ds005398.v1.1.3

    The publication analyzes released event marks and channel metadata from OpenNeuro ds005398 v1.1.3.

  5. doi:10.1111/epi.18545

Cited by

3 publications

Public catalog entries on Sciscape.