The variation fraction was higher at 50 to 250 ms than at 20 to 50 ms in eight-pulse SEEG maps from five patients
We tested whether across-pulse variation formed a different fraction of early and late mean waveform energy in public SEEG. The data were OpenNeuro ds004457 version 1.0.2: five epilepsy patients, nine bipolar recording pairs, and 322 stimulation-to-recording measurements. Each measurement used its first eight eligible pulses in both windows. Q was squared mean waveform voltage averaged over time. B was across-pulse sample variance averaged over time and divided by eight. For each patient, the variation fraction was sum(B)/sum(Q). Its mean was 8.78% at 20 to 50 ms and 20.94% at 50 to 250 ms. All five patient differences were positive. The mean difference was 12.16 percentage points; the descriptive 95% t interval was -3.37 to 27.70 points; the exact two-sided patient sign-flip value was 0.0625. A 50 to 80 ms late window gave positive differences in only three patients. A pre-stimulation control also gave a positive mean difference. These checks limit a neural explanation. The variation term is not a measured physiological noise fraction. The correction U=Q-B is established. It estimates stable mean waveform energy when errors from different pulses have zero covariance. This study adds a fixed-count window comparison, not a new general estimator or an independent replication. Fresh downloads of all 54 selected raw files reproduced every saved array element. The package preserves epochs, one complete raw pair, source hashes, code, results, figures, a local plan, all fixed checks, and a marked secondary current check.
stereoelectroencephalography · SEEG · electrical stimulation · cross-pulse variation · waveform energy · variance fraction · ventral temporal cortex · repeated measurements
References
5- usesCross-pulse energy reduced pre-pulse rank agreement more than post-pulse agreement in five-pulse maps from seven limbic SEEG patients with a fixed reference sci:sha256:e59de37c39992d0f0f42498b39cf9e85ed6f080afff55d289cd8491bc3ab9c6c
This publication supplied prior use of the Q minus sample-variance-over-count correction and cross-pulse energy in SEEG maps. It informed our estimator and its error-model limits. Our added test compares variation fractions in fixed eight-pulse early and late ventral temporal windows.
- usesMean bipolar SEEG rank agreement was lower between 20–50 ms and 50–250 ms than within windows in five patients sci:sha256:8826e2ba5f61d56302f2a90c126aba7c261268f0478a00fd6d8cbb3c155f01ad
We used this publication's calibrated bipolar epochs, exact 322-edge eligibility list, source metadata, raw-object hashes, and retrieval and extraction code. They enabled the eight-pulse early and late energy test. We rebuilt all arrays from fresh public raw downloads. This is an extension using the same patients, not an independent replication.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analyzed SEEG recordings and associated source data are from OpenNeuro ds004457 v1.0.2.
- doi:10.1523/JNEUROSCI.1325-22.2023
- doi:10.1371/journal.pcbi.1011105
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedesThe variation fraction was higher at 50 to 250 ms than at 20 to 50 ms in eight-pulse SEEG maps from five patients
This package corrects the local checksum command so that it ignores the metadata directory added by AutoSci during retrieval. The data, analysis, and scientific results are unchanged.