Mean bipolar SEEG rank agreement was lower between 20–50 ms and 50–250 ms than within windows in five patients
We compared response ranks in five public SEEG recordings from OpenNeuro ds004457, version 1.0.2. We used nine bipolar pairs in ventral temporal sulci, with 322 edges and 1,998 distinct stimulation pulses. The early window was 20 to 50 milliseconds. The late window was 50 to 250 milliseconds. Mean rank correlation was 0.5015 between repeated early maps and 0.4503 between repeated late maps. Mean correlation between windows was 0.3736. The mean within-window correlation was 0.4759, giving a gap of 0.1023. The gap was positive in all five patients. The exact two-sided sign-flip result was p = 0.0625. These findings describe this clinical sample and do not establish a population effect. Time-block and within-pair checks retained the pattern. A background control before stimulation gave no positive mean gap. The package preserves code, calibrated epochs, a complete raw example pair, source tables, object hashes, results, and reproduction instructions. A separate calculation reproduced all main response values and correlations. A saved-data replay produced identical analysis files.
SEEG · electrical stimulation · response window · rank agreement · repeatability · ventral temporal cortex · OpenNeuro
References
2- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analysis uses the public SEEG recordings, stimulation events, channel labels, and electrode coordinates from OpenNeuro ds004457 version 1.0.2.
- doi:10.1523/JNEUROSCI.1325-22.2023
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesThe variation fraction was higher at 50 to 250 ms than at 20 to 50 ms in eight-pulse SEEG maps from five patients
We used this publication's calibrated bipolar epochs, exact 322-edge eligibility list, source metadata, raw-object hashes, and retrieval and extraction code. They enabled the eight-pulse early and late energy test. We rebuilt all arrays from fresh public raw downloads. This is an extension using the same patients, not an independent replication.
- usesMean late response rank agreement decreased from 0.564 to 0.452 after sample variance subtraction in five selected SEEG patients
We used its calibrated SEEG epochs, fixed contact and trial selection, source tables, and pinned raw retrieval recipes. We checked archive hashes and rebuilt all five epoch files from fresh source downloads. The new energy test uses the same clinical sample.
- usesThe variation fraction was higher at 50 to 250 ms than at 20 to 50 ms in eight-pulse SEEG maps from five patients
We used this publication's calibrated bipolar epochs, exact 322-edge eligibility list, source metadata, raw-object hashes, and retrieval and extraction code. They enabled the eight-pulse early and late energy test. We rebuilt all arrays from fresh public raw downloads. This is an extension using the same patients, not an independent replication.