sciscape Publications
← All publications

A sign flip test did not detect a hippocampal 8–20/4–8 Hz power ratio change from fixation to late maintenance in 12 SEEG patients

We compared hippocampal power changes from fixation to late memory maintenance in public SEEG. The higher band was 8 to less than 20 Hz. The lower band was 4 to less than 8 Hz. A local plan fixed the contrast before calculation. The study used 1,000 successful trials with a zero source artifact flag. It used 44 matched bipolar pairs from two sessions in each of 12 patients with epilepsy. Loads, sessions, and patients had equal weights at their respective steps. The mean change in the log band ratio was -0.375 dB. The 95% t interval was -0.823 to 0.074 dB. An exact two-sided patient sign flip test gave p = 0.0947265625. The test did not detect a ratio change. This does not establish equal band changes. The exact test assumes independent patients and sign symmetry under the null. All planned descriptive checks are included. Fresh fixed-version public records verified both primary windows in all 1,167 source trials. Separate Fourier and ratio code verified the inputs and primary result. The package preserves spectra, raw excerpts, source metadata, retrieval identities and hashes, source code, results, and instructions. This is a task-phase association in a selected clinical sample. It does not isolate a memory mechanism or separate periodic from aperiodic power.

stereoelectroencephalography · hippocampus · working memory · power spectra · band power · sign flip test

Admitted 0 citing publications

References

4
  1. usesThe estimated mean change in hippocampal theta load slope across delay halves was 0.118 dB per two letters in 12 SEEG patients sci:sha256:f00f08a8543108f38c9e890fccb4a125055d9f2e338e987aeda5174bbb65cdc1

    This archive supplied early and late one-second delay spectra, full-delay digital bound flags, raw examples, and full-source verification records. We checked its full manifest and used the late spectra in the new fixation-to-maintenance band ratio contrast. Fresh public late records verified every primary source trial.

  2. usesA sign flip test did not detect a fixation theta slope for previous exported trial load in 12 SEEG patients across two sessions sci:sha256:1e267286409876b66bdbf4d064d2a6fc31f45c40e25c31c294ea9936af940f88

    This archive supplied one-second fixation spectra, raw examples, source object identities, and metadata. We checked its full manifest and matched these inputs to delay spectra. Fresh public fixation records verified every primary source trial.

  3. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analysis used OpenNeuro ds004752 version 1.0.1, including its source records and metadata.

  4. doi:10.7554/eLife.78677

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.