Clipped acoustic fits did not pass a shared 1% voice pattern error test in 20 iEEG patients and 16 fMRI adults

We tested whether acoustic fits learned from non-vocal source labels predict response differences among non-speech human voices. Separate public studies supplied signed field potentials from 20 reserved iEEG patients and BOLD estimates from 16 reserved fMRI adults. Each person had a separate fit. Category and scaled spatial means were removed. Four development people per modality selected the ridge penalty before the reserved test. Mean error fell by 1.75% and 11.30% relative to centered target energy. Joint person and test-sound 95% ranges were 0.21% to 3.30% and 6.55% to 15.76%. The fixed shared rule required a gain above 1% in both modalities. It did not pass because the iEEG range extended below that margin. Resampling training sounds gave an iEEG range of -0.81% to 2.85%. Without acoustic clipping, all 20 iEEG scores were negative; fMRI changed little. An exploratory feature audit found a target electrical-source descriptor about 497 training standard deviations from its training mean. The result provides a restricted prediction benchmark, not a stable general acoustic code or a causal claim. The package preserves code, permitted inputs, source pins, all outcomes, plans, figures, and repeat instructions. Original unlicensed author files remain external.

human auditory cortex · iEEG · fMRI · acoustic encoding · held-out sound class · prediction error · extrapolation

Admitted 1 citing publication

References

9
  1. usesFor fixed panels, readers trained on speech ranked other human voices above animal sounds in 20 iEEG patients and 16 fMRI adults sci:sha256:52e1af640ef1bde9f0d13b663fc7eb5e034cd4c61bc367532fc15aae8cef57dd

    We reuse the permitted electrical derivative, source records, and input routines.

  2. usesOne iEEG panel and eight fMRI adults showed small pattern transfer across labels for 49 sounds, but centered BOLD error exceeded baseline sci:sha256:fce5ce660523de796311505b1b20c40fdccf3a250aeb008d1ad8a101e2c3b62d

    Its distinction between pattern alignment and calibrated error motivated the new primary endpoint.

  3. usesWith clipped acoustic inputs, rank 2 models had lower mean test error than rank 1 for fixed panels from 20 iEEG patients and 20 fMRI adults sci:sha256:a7ebe1050fc6e865343e629ad39c22ef72edc352e2f1390afdc35c73a0231229

    Source extraction and fresh source-check routines descend from this work.

  4. doi:10.5281/zenodo.20599001
  5. doi:10.1016/j.cub.2026.07.063
  6. doi:10.1152/jn.00588.2020
  7. doi:10.1371/journal.pbio.3002366
  8. doi:10.1016/j.cub.2022.01.069
  9. doi:10.1371/journal.pcbi.1003412