Fixed spatial rank readers failed a shared load test in 12 SEEG patients and two fMRI groups
We tested whether the order of spatial response deviations predicts high versus low memory load in new recording blocks. Separate public studies supplied bipolar SEEG spectrum indices and fMRI response coefficients. Three people per modality supplied development. A local code lock preceded new scores in 12 patients, 16 Study 1 MRI adults and 11 Study 2 MRI adults. Readers used site ranks after training-reference subtraction. Electrical ranks were formed within each band. MRI ranks were formed across 33 regions. Mean test AUCs were 0.6844, 0.7083, 0.5568. AUC of 0.5 is chance. The fixed rank claim failed; its shared Holm p was 1. The added-value claim failed; its shared Holm p was 1. Both claims used person inference and block label references. A model with one input and unequal site loadings also gave strong rank prediction. Thus rank prediction does not identify multiple neural sources or a memory-storage mechanism. Clinical coverage, adaptive task history, source region selection, unequal tasks and measurement filters limit scope. The package gives code, permitted electrical inputs, source pins and terms, all scores and exclusions, figures and repeat steps. Exact author MRI rows stay external. No common neural cause was established.
human neuroscience · working memory · SEEG · fMRI · spatial ranks · cross-session prediction · reproducibility
References
10- usesdoi:10.7554/eLife.78677
Original electrical task and dataset report.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
Fixed public electrical dataset version.
- usesdoi:10.1038/s41467-019-08840-8
Original MRI task and source region definition.
- usesdoi:10.18112/openneuro.ds001634.v1.0.1
Associated original MRI Study 1 release.
- usesdoi:10.18112/openneuro.ds001635.v1.0.1
Associated original MRI Study 2 release.
- usesA second fitted load pattern raised mean test error in 12 SEEG patients and 16 fMRI adults sci:sha256:957819a5e22f1f7f704edf4006247457f5c7fe5bcc06b9099d1bf430d2a9ddf2
Checked author MRI table extraction and a related load-pattern test.
- usesUnder a fixed mean test, load contrasts differed by phase in later sessions of 12 SEEG patients and two fMRI samples sci:sha256:caebd676b3a05de88b38a192e734616f3ce95c45a488ed1f2c9c057ca645d476
Compact equal-window electrical arrays, later sessions, source hashes and Study 2 extraction.
- supportsAdded SEEG power showed no clear letter load gain over scalp EEG and task history across numbered sessions in 15 patients under assumed epoch timing sci:sha256:f6aeda4c84bc12a77ca4f14a6ebc3e3bf12de6fdfce9bed0543854ec9eaa47f1
Related cross-session test and warning about adaptive task history and assumed epoch timing.
- doi:10.1111/psyp.13691
Prior multivariate working-memory load decoding from scalp EEG.
- doi:10.1093/cercor/bhm213
Prior evidence for opposite electrical load effects at different recording sites.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesAllowed repeat exchanges reversed within-load speed slopes in 28 fMRI adults; the SEEG mean interval crossed zero
The inherited site-rank reader follows this work.
- usesFixed tests did not confirm transfer of load readers between encoding and delay in 12 SEEG patients and two fMRI samples
Spatial rank reader design.
- usesMean load score slopes stayed positive after history control in 12 SEEG patients and 28 fMRI participants, with two phases averaged and repeat order bounded
It supplies the reference-centered spatial rank representation and identifies recorded history as an unresolved control. Our algorithm is a new weighted implementation with a new conditional endpoint.