Under a fixed mean test, load contrasts differed by phase in later sessions of 12 SEEG patients and two fMRI samples
We tested whether high-minus-low load response vectors share structure and differ between encoding and delay. Separate human studies supplied SEEG and fMRI. Cross-block products used scale estimates from an unused third block. First tests used 11 SEEG patients and 16 and 11 fMRI adults. All shared claims failed. Phase-change means were 0.03422, 1.15524 and 0.36559. A separate fixed follow-up processed all 42 unused electrical sessions in the 12 reserved patients. 39 sessions in 12 eligible patients entered its primary; sessions were averaged within people. The new electrical phase-change mean was 0.12172, with 95% person t interval [0.03002, 0.21342]. The later-session phase-change test passed the fixed numerical rule in all three study groups. Its four-claim Holm p was 0.0277974. Shared-structure tests failed. Correct-only and history checks were uncertain. The follow-up reuses people and known MRI scores; it is not independent cross-modal confirmation. A common-code simulation gave positive ordinary squared distance without true change. A gain change alone gave positive corrected change. The nominal shared-structure t test also had an 8% false-positive rate at a 5% level in one specified noise model. Source selection, adaptive trial history, measurement filters and distinct cohorts limit inference. The package adds 3.40 MB of compact phase data from 6.11 GB of checked raw inputs, code, plans, all scores, figures, audits and repeat steps. It does not establish a common neural code or causality.
working memory · SEEG · fMRI · cross-validation · load contrast · phase change · public data · replication
References
11- usesFixed tests did not confirm shared load or phase changes in response spread in 12 SEEG patients and two fMRI samples sci:sha256:d1e3679b2da22e5c32e420354d1e433cc7301d780f5e8f6b53b9e2c359fa757a
Unchanged equal-window session 01 electrical features, source audits and MRI extraction code.
- In one session of 15 patients, SEEG load decoders showed no clear cross-period transfer, while pooled training showed no significant loss sci:sha256:107a7d1ff4f20e7663f455558771404dbda131d8f3c973878a2c1f5057cf597e
Earlier cross-period classifiers in the source electrical cohort motivate a direct change test; not a new-cohort replication.
- usesA second fitted load pattern raised mean test error in 12 SEEG patients and 16 fMRI adults sci:sha256:957819a5e22f1f7f704edf4006247457f5c7fe5bcc06b9099d1bf430d2a9ddf2
Original author-table MRI parser, reused through SCI 718584a2.
- doi:10.7554/eLife.78677
- doi:10.18112/openneuro.ds004752.v1.0.1
- doi:10.1038/s41467-019-08840-8
- doi:10.18112/openneuro.ds001634.v1.0.1
- doi:10.18112/openneuro.ds001635.v1.0.1
- doi:10.1016/j.neuroimage.2015.12.012
- doi:10.1371/journal.pcbi.1005508
- doi:10.1016/j.neuroimage.2023.120258
Cited by
7 publicationsPublic catalog entries on Sciscape.
- usesA fixed test did not confirm smaller high-load response steps during delay in 12 SEEG patients and 16 fMRI adults
Upstream equal-window electrical extraction and later-session provenance, inherited through e33513c2.
- usesAllowed repeat exchanges reversed within-load speed slopes in 28 fMRI adults; the SEEG mean interval crossed zero
This source supplies the compact phase-spectrum extraction chain and preserved raw-source provenance.
- usesFixed tests did not confirm transfer of load readers between encoding and delay in 12 SEEG patients and two fMRI samples
Later-session electrical extraction and raw-check code.
- usesFixed spatial rank readers failed a shared load test in 12 SEEG patients and two fMRI groups
Compact equal-window electrical arrays, later sessions, source hashes and Study 2 extraction.
- usesTwo assumed repeat orders gave opposite fMRI mean load history slopes in 28 adults; shared tests with 12 SEEG patients failed
We reuse its compact electrical phase arrays and source receipts, and its checked MRI table layout.
- usesMean load score slopes stayed positive after history control in 12 SEEG patients and 28 fMRI participants, with two phases averaged and repeat order bounded
It supplied the licensed two-phase electrical spectrum arrays and raw-source receipts, obtained through SCI 1de7c2d5.
- usesA fixed area test did not confirm shared load direction changes in 12 SEEG patients and two fMRI samples
We reuse its checked compact phase inputs and MRI extraction chain, and test its stated limitation that vector differences permit scalar gain.