A fixed test did not confirm smaller high-load response steps during delay in 12 SEEG patients and 16 fMRI adults
We tested whether measured working-memory response steps are smaller from medium to high load than from low to medium load. Separate public studies supplied SEEG from 12 epilepsy patients and fMRI from 16 adults. The electrical loads were 4, 6 and 8 letters; MRI loads were 3, 5 and 7 items. One data block set feature scales. Two other blocks supplied response-step products. Spatial means were removed. Sessions and domains were averaged within people. A local code lock preceded reserved-person scores for this new endpoint. Mean compression was +0.00481 in SEEG and +0.04423 in fMRI. The respective 95% person Student limits were [-0.02524,+0.03486] and [-0.02978,+0.11824]. The fixed shared rule failed, with gate p=0.73123. All fourteen fixed controls also had compression intervals through zero. Added history and repeat-variation checks remain descriptive. An independent calculation matched all 67 primary development and test records. A second decoder matched every MRI source row. Two fresh raw SEEG rebuilds matched stored features. A clean replay matched all 107 numerical result files. Model checks show that unequal noise can bias ordinary step comparisons and that shared block errors can also defeat the separate-block method. This is a checked conditional assay and a complete negative benchmark. It does not establish equal steps, absent compression, a memory capacity or a common neural cause. Code, permitted compact inputs, source versions and terms, plans, figures and repeat instructions are supplied. Exact MRI rows remain external.
working memory · SEEG · fMRI · response geometry · load compression · negative result · noise bias · reproducible methods
References
12- usesA fixed area test did not confirm shared load direction changes in 12 SEEG patients and two fMRI samples sci:sha256:f8909ce636c734620f147d23010eac763525985ee2747b3c15b0a01c9f5f3008
Reuse its verified compact electrical data, provenance and MRI extraction code; test a different directional load-step endpoint.
- A second fitted load pattern raised mean test error in 12 SEEG patients and 16 fMRI adults sci:sha256:957819a5e22f1f7f704edf4006247457f5c7fe5bcc06b9099d1bf430d2a9ddf2
Its undirected curvature and extra-direction tests motivate a signed comparison of adjacent load steps.
- A fixed test did not confirm shared concavity of load responses in EEG and fNIRS from 20 reserved participants sci:sha256:843572569b994166bd101eaf4218c97fc0f9656833ff6596b35d3a80aeee82d8
Related fixed concavity test in other human modalities; no neural data reused.
- usesUnder a fixed mean test, load contrasts differed by phase in later sessions of 12 SEEG patients and two fMRI samples sci:sha256:caebd676b3a05de88b38a192e734616f3ce95c45a488ed1f2c9c057ca645d476
Upstream equal-window electrical extraction and later-session provenance, inherited through e33513c2.
- usesFixed tests did not confirm shared load or phase changes in response spread in 12 SEEG patients and two fMRI samples sci:sha256:d1e3679b2da22e5c32e420354d1e433cc7301d780f5e8f6b53b9e2c359fa757a
Upstream first-session electrical arrays and MRI reader, inherited through e33513c2.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
Fixed-version human SEEG recordings and task metadata.
- usesdoi:10.18112/openneuro.ds001634.v1.0.1
Acquisition-study provenance for the separately pinned MRI author table; raw images were not reprocessed.
- doi:10.7554/eLife.78677
Electrical source task, neural study and error-followed-by-low-load schedule.
- doi:10.1038/s41467-019-08840-8
MRI source methods, task, load levels and regional response table.
- doi:10.1093/cercor/bhx351
Prior limits on capacity interpretations from neural response curves.
- doi:10.1371/journal.pcbi.1005508
Established representational geometry and separate-block distance framework.
- doi:10.7554/eLife.82566
Established inference on representational geometries and the role of independent people and conditions.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.