A fixed area test did not confirm shared load direction changes in 12 SEEG patients and two fMRI samples
We tested whether memory-load responses change direction between encoding and delay beyond arbitrary changes in strength. One data block chose a plane. Two other blocks supplied a signed area. Its expectation is zero for one stable response direction under independent block errors. Public, separate studies supplied 12 SEEG patients with 50 eligible sessions, 16 fMRI adults and 11 other fMRI adults. Development used two eligible patients and three MRI people. Fixed test mean areas were +0.004334, +0.090675 and -0.017008. Their 95% person t intervals were [-0.001679,+0.010347], [+0.054251,+0.127099] and [-0.052561,+0.018546]. The single shared positive rule failed, with p=0.84423. A positive digital-bound electrical check did not replace that failure. A weaker phase-distance reference was positive in all groups but permits pure strength changes. Independent pair-coordinate arithmetic matched all 77 primary records. Simulations separated known strength and direction changes; shared block errors caused false positives. These are new-endpoint tests in reused cohorts, not new-cohort confirmation. The package gives the proof, code, source versions and terms, compact permitted inputs, plans, all failures, figures and repeat instructions. No shared neural direction change, equivalence, or causality is claimed.
working memory · SEEG · fMRI · response geometry · cross-validation · negative result · measurement error
References
11- usesUnder a fixed mean test, load contrasts differed by phase in later sessions of 12 SEEG patients and two fMRI samples sci:sha256:caebd676b3a05de88b38a192e734616f3ce95c45a488ed1f2c9c057ca645d476
We reuse its checked compact phase inputs and MRI extraction chain, and test its stated limitation that vector differences permit scalar gain.
- usesFixed tests did not confirm shared load or phase changes in response spread in 12 SEEG patients and two fMRI samples sci:sha256:d1e3679b2da22e5c32e420354d1e433cc7301d780f5e8f6b53b9e2c359fa757a
Its equal-window first-session electrical arrays and source extraction code came through the direct input publication.
- usesSleep map shape tests passed in 19 SEEG patients and 15 fMRI records under independent window errors sci:sha256:78fcb770777fbbab168a2bc594be45af3003917f035ae9124bebaec9cd4d42d4
Its related area-algebra test motivates the proportional-vector null. Our three-block plane test permits correlated phase errors within a block.
- doi:10.7554/eLife.78677
- doi:10.18112/openneuro.ds004752.v1.0.1
- doi:10.1038/s41467-019-08840-8
- doi:10.18112/openneuro.ds001634.v1.0.1
- doi:10.18112/openneuro.ds001635.v1.0.1
- doi:10.1016/j.neuroimage.2023.120258
- doi:10.7554/eLife.82566
- doi:10.1016/j.neuroimage.2026.121737
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA fixed test did not confirm smaller high-load response steps during delay in 12 SEEG patients and 16 fMRI adults
Reuse its verified compact electrical data, provenance and MRI extraction code; test a different directional load-step endpoint.