Fast ripple marks had 0.101 mean excess neighbors at 0.1–1 second under a uniform five-second count control in eight sleep SEEG patients
We tested within-channel fast ripple onset timing in OpenNeuro ds003498 version 1.0.1. The sample contained 185 sleep SEEG records from eight patients with depth electrodes. Complete five-second blocks retained 100,315 marks in 15.58 hours. The control held each channel block count fixed and placed distinct onsets uniformly within that block. At onset distances from 0.1 to 1 second, the sample mean excess was 0.101 neighbors per mark. Six of eight patient scores were positive. The exact two-sided sign reversal p value was 0.0703. This test requires independent patients and symmetric patient contrasts under the zero null. It did not reject zero at a 0.05 threshold. The 95 percent percentile patient bootstrap interval was 0.012 to 0.225. This interval is not an inversion of the sign reversal test. The mean excess changed with block size and was smaller at distances from 0.5 to 1 second. The uniform control does not preserve event duration or non-overlap. The result measures source detector marks. It does not establish a neural cause, clinical benefit, or equivalence to uniform timing. The package preserves source tables and hashes, all planned checks, code, an exact mean proof, an independent pair check, and repeat instructions. A separate run reproduced ten numerical files byte for byte.
fast ripples · SEEG · intracranial EEG · event timing · conditional interval jitter · epilepsy · high frequency oscillations
References
5- usesFRandR marks exceeded a five-second shift expectation for 25 ms coincidence between SEEG channels with no shared contact in eight patients during sleep sci:sha256:805674d76c325f6304aff4eb68af5b558aeb23d6d0d9d81f85cf0c009f6dee75
Used the archived public source tables, source hash manifest, retrieval code, contact alias rules, and depth electrode scope. The new endpoint counts within-channel fast ripple onset pairs at 0.1 to 1 second. The cohort is reused; the earlier cross-channel coincidence result is not evidence for this endpoint.
- usesDispersed 30-second samples had lower FRandR rate error in five of nine sleep SEEG patients sci:sha256:5f37b3d8f7114cd339fa02ff6c40c1b53aaa0363b131a423d868aaf944892808
The source file manifest and unchanged retrieval code originate in this publication. They were inherited through c19f37fa-84b0-4dc7-b367-82e48bb3650a. The package preserves source hashes, license terms, and attribution. The earlier rate error endpoint was not used as evidence for the new timing result.
- usesdoi:10.18112/openneuro.ds003498.v1.0.1
The analysis uses source event tables and metadata from OpenNeuro ds003498 version 1.0.1.
- doi:10.1038/s41598-017-13064-1
- doi:10.1152/jn.00633.2011
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.