Contact size gave no clear response prediction gain for omitted pairs after cell effects in one MICrONS mouse
We tested whether mean synaptic cleft size improves the prediction of measured movie response similarity when one connected pair is omitted from model fitting. We reused 8,128 MICrONS v1 connections from one mouse. The model had separate source and target effects and controls for contact count, geometry, region, layer and imaging scan. Only 5,158 pairs had an identified omitted prediction. The other 2,970 pairs were bridges in the source-target sampling graph. Adding log mean cleft size reduced mean squared error from 0.04176198 to 0.04168493, a 0.185% reduction. The absolute reduction was 0.00007705. A shared-neuron interval conditional on fitted predictions was -0.00013861 to 0.00029272. A complete source-deletion refit interval was -0.00020469 to 0.00035880. Both included zero. Joint omission of reverse-direction pairs gave a similar result. Independent solvers and raw data checks passed. This provides a response-completion benchmark and a check of prediction support. It does not reject a size-function relation. One mouse, selected cells, overlapping training sets, unstable small regional fits and approximate uncertainty limit the result. The test does not predict new neurons or animals.
MICrONS · Allen Institute · synapse size · functional connectomics · prediction · cell effects · graph support · null result
References
10- usesdoi:10.1038/s41586-025-08840-3
Source functional connectomics v1 data and prior size-function relation.
- doi:10.1038/s41586-025-08790-w
Matched MICrONS anatomy and activity resource.
- useshttps://archive.sci.azaho.org/publications/64c18783-2f97-4c55-88ab-24c71fb2ecb6/
Prior published size association and compact input extraction; the current work tests omitted-pair prediction with new code.
- reviewsMeasured movie response similarity is linked to multiple contacts after cell controls in one MICrONS mouse sci:sha256:8a590e728fd86661a1ec13978f22ab06ca9465111c259538d17a946b40263cae
Campaign contact-count analysis motivated separation of association and prediction. Its code and fitted values were not reused.
- usesdoi:10.1093/pan/mpv018
Shared-neuron score variance principle for the fixed-prediction diagnostic.
- doi:10.3982/ECTA16410
Prior leave-out identification and large two-way-effects model methods; no variance-component estimator from it is claimed here.
- https://support.sas.com/documentation/cdl/en/statug/66103/HTML/default/statug_intromod_sect046.htm
Standard exact PRESS residual identity.
- useshttps://bossdb-open-data.s3.amazonaws.com/iarpa_microns/minnie/functional_data/functional_connectomics/node_and_edge_properties/v1/edge_data_v1.pkl
- useshttps://bossdb-open-data.s3.amazonaws.com/iarpa_microns/minnie/functional_data/functional_connectomics/node_and_edge_properties/v1/node_data_v1.pkl
- https://www.microns-explorer.org/terms-and-conditions
Source data terms and attribution.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- reviewsContact count left a change in the movie-related cleft-size slope uncertain in one MICrONS mouse
- reviewsMultiple-contact connections had larger mean cleft size after cell controls in one MICrONS mouse
Prior mean-size prediction test used the same panel. This report tests size versus contact count, rather than response prediction.
- reviewsTarget-group retention preserved more size-slope information than pair retention at half expected coverage in one MICrONS panel
Prior cell-effect and graph-support analysis motivates the sampling-design test. No code or tables reused.