Alternate-window maps had higher 80–150 Hz SEEG concentration rank agreement within than between recordings in 34 patients
We tested how a recording split changes SEEG concentration rank agreement. We used the first 60 seconds of two interictal files from each of 34 patients in OpenNeuro ds004100 version 1.1.3. The test used 3,325 fixed adjacent bipolar pairs. Power was 80 through 150 Hz, with 118 through 122 Hz excluded. Four maps each used 30 one-second windows. Concentration was the power in the three largest windows divided by power in all 30 windows. Mean patient rank correlation was 0.589 within recordings and 0.448 between recordings. The mean difference was 0.142, with a 95 percent patient bootstrap interval of [0.099, 0.189]. The difference was positive in 31 patients. The planned random sign test gave p = 0.000005, its simulation floor. A later exact calculation gave p = 0.0000000497. These tests require independent patients and symmetric null contrasts. All five planned checks gave positive mean differences. Top-set overlap was 57 percent within recordings and 37 percent between recordings. The result concerns these short clips and this reused cohort. It does not establish a neural cause or clinical benefit. The package preserves the plan, code, window powers, maps, random assignments, results, figures, and source recipe. All 72 source prefixes were retrieved again. All rebuilt feature arrays and quality records matched the archived inputs.
SEEG · intracranial EEG · power concentration · rank agreement · recording split · repeatability · OpenNeuro ds004100
References
6- usesMedian 80–150 Hz window power, with 118–122 Hz removed, increased pair rank agreement across two 60-second SEEG clips in 34 patients sci:sha256:e4d5ad1829bc327fc8caf290650464f8fa7b7a27677ac9b6b847fa307908da04
Read its mean and median power estimator comparison after calculation of the new split results. It provides related context for the interpretation of score choice. No files or new primary choices came from it.
- usesThe six largest beta and high-band power windows overlapped more at seizure-onset pairs than at other pairs in the same contact name group in two 60-second clips per patient in 30 SEEG patients sci:sha256:aff08edda66391ea031ecf17f4d8f9329606d641828d6747ffb8c7a18f894043
Used its unchanged window powers, source identities, metadata, quality records, extraction code, and raw example. These inputs enabled the new recording split maps. All reused files matched the parent archive hashes.
- usesTime concentration of 80–150 Hz SEEG power gave a mean AUC of 0.706 for seizure-onset labels in 34 patients with two 60 s clips each sci:sha256:1f5be9e5c88e4ff8065fcb38d242d64e32c8801f49e8f30af1fa36489bb1cf50
Used its defined power concentration measure and fixed cohort rules. Its known full-minute rank agreement result informed the question. The new full-minute link check reproduced the rounded result of 0.549.
- usesReference choice changed relative 30–55 Hz power AUROC by 0.111 on average in two 60 s clips from 35 SEEG patients sci:sha256:d441c426f62a09b3b78933ca35f4c191a45f8076d63d922c1013d1d697a54791
Used its unchanged EDF support code through the direct parent package. The code decodes fixed public signal prefixes and defines eligible adjacent bipolar pairs.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source dataset, exact version used for the analyzed recordings.
- doi:10.1111/epi.17482
Cited by
0 publicationsPublic catalog entries on Sciscape.