Median 80–150 Hz window power, with 118–122 Hz removed, increased pair rank agreement across two 60-second SEEG clips in 34 patients

We tested mean and median window power in two 60-second interictal SEEG clips from each of 34 patients. The source was OpenNeuro ds004100 version 1.1.3. The band was 80–150 Hz, with 118–122 Hz removed. We used 3,325 fixed bipolar pairs and 60 one-second windows per clip. Mean patient rank agreement increased from 0.9486 with mean power to 0.9639 with median power. The mean change was 0.0153, with a 95 percent patient bootstrap interval of [0.0046, 0.0296]. The exact patient sign flip test gave p = 0.001041 under independent-patient and sign-symmetry assumptions. Agreement increased in 24 patients and decreased in 10. All four planned checks gave positive mean changes in rank agreement. Clinical seizure onset label AUC changed by -0.0039 [-0.0099, 0.0014]. The two-second check gave a small negative AUC change. Thus, greater agreement does not establish preserved label separation or neural accuracy. This is a new analysis of an existing cohort. The package preserves the fixed plan, code, window powers, new scores, patient results, figures, and source recipe. All 72 source prefixes were downloaded again. All 68 rebuilt feature files and 36 QC records matched exactly.

stereoelectroencephalography · high-frequency power · median estimator · inter-run agreement · seizure onset zone · robust statistics

Admitted 9 citing publications

References

4
  1. usesTime concentration of 80–150 Hz SEEG power gave a mean within-shaft AUC of 0.720 for seizure-onset pairs in 30 patients with two 60 s clips each sci:sha256:7ef8ec6049a5486c854f10f036b25fc59368c98c7d1a4b982aaad8209bef019f

    Used its local comparison question to define a secondary within-contact-name-group check. The present check gives equal weight to eligible positive-negative comparisons and uses new median scores.

  2. usesTime concentration of 80–150 Hz SEEG power gave a mean AUC of 0.706 for seizure-onset labels in 34 patients with two 60 s clips each sci:sha256:1f5be9e5c88e4ff8065fcb38d242d64e32c8801f49e8f30af1fa36489bb1cf50

    Used its fixed cohort, window powers, source identities, QC records, and extraction code. Its trimming result informed the median question. The present study adds new median scores and patient-level estimator comparisons.

  3. usesReference choice changed relative 30–55 Hz power AUROC by 0.111 on average in two 60 s clips from 35 SEEG patients sci:sha256:d441c426f62a09b3b78933ca35f4c191a45f8076d63d922c1013d1d697a54791

    Used its unchanged EDF support code through the parent package. The code decodes pinned public signals and defines eligible adjacent bipolar pairs.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source data: HUP iEEG Epilepsy Dataset, OpenNeuro ds004100 version 1.1.3.