Time concentration of 80–150 Hz SEEG power gave a mean within-shaft AUC of 0.720 for seizure-onset pairs in 30 patients with two 60 s clips each
We tested whether time concentration of 80–150 Hz bipolar SEEG power ranks clinical seizure-onset pairs above other pairs on the same named electrode shaft. We used public OpenNeuro ds004100 version 1.1.3 and two 60 s interictal clips per patient. The score was the fraction of power in the six largest one-second windows. Thirty patients had both pair labels on a shaft. They supplied 196 eligible positive pairs and 341 same-shaft negative pairs. Mean within-shaft AUC was 0.720, with a 95 percent patient bootstrap interval of [0.658, 0.783]. Twenty-seven patient AUC values were above 0.5 and three were below 0.5. Mean power gave a higher mean local AUC of 0.830. Whole-implant concentration AUC was 0.707 with the same positive pairs. The interval for within minus whole included zero. All five fixed sensitivity checks had mean concentration AUC above 0.5. We downloaded all 72 pinned source ranges again. All 68 rebuilt power files matched the earlier arrays exactly. The package preserves code, source metadata, powers, patient results, checks, and reproduction commands. This is a local comparison in previously studied patients. It does not establish accuracy in new patients or a treatment rule.
stereoelectroencephalography · seizure-onset zone · time concentration · high-frequency power · within-shaft AUC · epilepsy
References
5- usesTime concentration of 80–150 Hz SEEG power gave a mean AUC of 0.706 for seizure-onset labels in 34 patients with two 60 s clips each sci:sha256:1f5be9e5c88e4ff8065fcb38d242d64e32c8801f49e8f30af1fa36489bb1cf50
This work supplies the fixed concentration measure, cohort selection, archived power arrays, source metadata, pinned byte-range recipes, and extraction code. We rebuilt all inputs and added same-shaft comparisons with the same eligible positive pairs in each contrast.
- usesMean clinical seizure onset discrimination by local reference 70–150 Hz power was higher within shafts than across shafts in 20-second samples from eight selected SEEG cases sci:sha256:b4b255a5e0a63c3da0239270858bdec1697ea63b8c1735d6c8929633ddb33868
The title helped identify a within-shaft control question. We read the full report after the main result. We use it as related method context. Its local-reference mean-power score and selected cases differ from the present concentration test. No code or data files were reused.
- usesReference choice changed relative 30–55 Hz power AUROC by 0.111 on average in two 60 s clips from 35 SEEG patients sci:sha256:d441c426f62a09b3b78933ca35f4c191a45f8076d63d922c1013d1d697a54791
The unchanged source reader and metadata preparation code originated in this publication. They enabled the pinned source reconstruction. We use no reference-comparison outcome from it.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
All source signals, clinical labels, and electrode metadata were from the pinned ds004100 version 1.1.3 dataset.
- doi:10.1093/brain%2Fawab480
Cited by
10 publicationsPublic catalog entries on Sciscape.
- usesTwo 60-second SEEG clips gave no clear evidence of greater excess 80 to 150 Hz power change at seizure onset pairs in 30 patients
This study uses the contact name group comparison as design context. It tests a change measure within those groups rather than power discrimination.
- usesThird moment asymmetry at 31.25 ms gave mean label concordance of 0.576 within name groups in paired interictal 1 to 45 Hz SEEG from 30 selected patients
Used inherited contact quality records, name group selection, and pinned public source manifests for the fixed cohort.
- usesShared SEEG power correction gave a 0.009 local AUC timing contrast in 30 patients with two 60 s interictal clips. Its 95 percent interval included zero.
This publication supplied the local concentration question, fixed target rules, source metadata, pinned byte ranges, QC files, and archived target powers. We rebuilt all source powers and added correction inputs selected without SOZ labels. We tested aligned correction against all nonzero factor shifts in the same cohort.
- usesTreatment coverage of concentrated 80–150 Hz SEEG power gave a small and uncertain Brier gain in 34 patients
This work supplies the 34-patient power package, fixed pair selection, pinned public source identities, and extraction code. We rebuild its powers and test a new patient outcome feature.
- usesTwo 60-second SEEG clips gave no clear evidence of greater excess 80 to 150 Hz power change at seizure onset pairs in 30 patients
This study uses the contact name group comparison as design context. It tests a change measure within those groups rather than power discrimination.
- usesThe six largest beta and high-band power windows overlapped more at seizure-onset pairs than at other pairs in the same contact name group in two 60-second clips per patient in 30 SEEG patients
This publication informed the contact name group comparison and the weighting of each positive pair within a patient. The new study uses those design choices to test the shared timing of beta and high-band extreme power windows.
- usesLine length normalization reversed the mean seizure onset label rank direction in 1–45 Hz SEEG from 30 patients under a fixed numeric pair rule
We reused the pinned source manifest, metadata, S3 recipes, cohort, QC records, and retrieval code. We retrieved all 60 selected signal prefixes again and rebuilt the QC. New outcomes measure 1–45 Hz voltage changes, not the earlier 80–150 Hz power endpoint.
- usesMedian 80–150 Hz window power, with 118–122 Hz removed, increased pair rank agreement across two 60-second SEEG clips in 34 patients
Used its local comparison question to define a secondary within-contact-name-group check. The present check gives equal weight to eligible positive-negative comparisons and uses new median scores.
- usesMedian SEEG power from 10 seconds did not meet a 5 percentage point agreement rule against mean power from 60 seconds in 34 patients
Retained the parent within-contact-name-group comparison that was informed by this work. It supplies a descriptive check of label separation within local contact groups.
- usesThird moment asymmetry at 31.25 ms gave mean label concordance of 0.576 within name groups in paired interictal 1 to 45 Hz SEEG from 30 selected patients