Observed mean test loss was higher for three-shaft MNI HFO fits than for pair fits in 18 sleep SEEG records with 1 s bins
We tested an added three-shaft term for HFO activity in public sleep SEEG data. We used MNI detector marks from 18 patients in OpenNeuro ds005398 version 1.1.3. We used 1 s bins and all 4,214 shaft triples. The first half-hour fitted each model. The next half-hour tested it. Each eight-state training table had a 0.5 cell pseudocount. The pair maximum entropy model kept all one-shaft and two-shaft margins of that table. Mean test loss was 1.130028289 nats for the pair model and 1.130102867 nats for the three-shaft model. Gain is pair loss minus three loss. The equal-patient mean gain was -0.000074578 nats per triple per bin. Its patient bootstrap 95% interval was [-0.000421963, 0.000335143]. The exact two-sided patient sign-flip p value was 0.729881. Five patients had a gain. The observed mean loss was higher with the added term. The interval includes a group gain and a group loss. Population use requires independent, exchangeable patients; the sign-flip null also requires joint sign symmetry. The package preserves the fixed plan, all source inputs, count tables, model probabilities, code, results, and instructions. All 94 fresh source checks passed. All 189 files in an offline repeat matched byte for byte. The test concerns released detector marks. It does not establish a distinct neural mechanism or clinical benefit.
high-frequency oscillations · stereoelectroencephalography · maximum entropy · held-out prediction · neural activity
References
4- usesMean pair coincidence of high HFO mark counts exceeded an independent block shift reference in 18 SEEG sleep records sci:sha256:54fa8a78f866c633a6d487954f5bb30beb03f4f1bfa9e0d22e771568541fe41a
This package supplied the exact compressed ds005398 source inputs, source lock, common.py, retrieve.py, and score-rule record. We reused those inputs and helpers. New shaft states, fitted probabilities, and test scores use the same 18 patients. Prior scores were not used as observations.
- usesMean triple HFO counts from eight SEEG patients were below a stationary three-channel pair reference for independent 50 ms bins sci:sha256:8a6497b1fab8c4cb5de484a4292c9fbeb298322662c65c6f7dc3cf1658a62d86
The earlier conditional triple-count test guided the question and the limit on causal interpretation. We tested later prediction loss in another dataset with all shafts and 1 s bins. We did not repeat its fixed-margin count test.
- usesdoi:10.18112/openneuro.ds005398.v1.1.3
The analysis used OpenNeuro ds005398 version 1.1.3; its fixed source commit and object versions are recorded in the package.
- doi:10.1111/epi.18545
Cited by
0 publicationsPublic catalog entries on Sciscape.