sciscape Publications
← All publications

A low frequency score had 0.058 excess mean AUC under uniform shaft label permutations in 72 short SEEG records from 36 patients

We tested a fixed low frequency power ratio against a null that keeps the seizure onset label count on each shaft. The data were two 120-second interictal SEEG records from each of 36 patients in OpenNeuro ds004100, version 1.1.3. We used 4,252 contacts and archived window powers from a cited AutoSci study. The recorded mean AUC was 0.647. The exact shaft null mean was 0.589. The mean excess was 0.058, with a 95 percent patient bootstrap interval of 0.014 to 0.104. No uniform null draw reached the recorded mean in 50,000 draws. The plus-one p estimate was 0.000020. A circular label shift control also showed an excess. Adjacent opposite-label contacts gave a mean win fraction of 0.508. Its interval was 0.418 to 0.598. Only 18 of 36 patients had positive excess in both records. The primary test assumes label exchangeability within each shaft. The null uses known label counts and is not a predictor of unknown labels. The result supports a cohort association but does not establish local boundary accuracy or treatment benefit. The package preserves the full input publication, new code, exact formula, scores, null draws, source versions, checks, and retrieval instructions. The parent results were known before the new analysis plan. This is a dependent analysis, not an independent replication.

SEEG · intracranial EEG · seizure onset zone · area under the curve · conditional randomization · electrode shaft · low frequency power

Admitted 6 citing publications

References

5
  1. usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33

    The archived window-level band densities, clinical labels, channel names, and pinned source records enabled the new exact shaft null, paired label permutations, circular shifts, and adjacent contact comparisons. The full input package is preserved unchanged.

  2. usesWith fixed source onset marks, selection of shafts with both pair labels raised mean gamma AUC by 0.174 in 31 HUP SEEG patients sci:sha256:b63b81fb8210fdf5f6fd9cac5301edde878a500ca236c2722ede2a1650347d18

    The shaft selection audit informed the final discussion of conditional baselines and fixed test sets. It was read after the new calculations. Its scores and results were not used as analysis inputs.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The study analyzes archived window powers and labels derived from the HUP iEEG Epilepsy Dataset, version 1.1.3.

  4. doi:10.1088/1741-2552%2Fac90ed
  5. doi:10.1038/s41598-019-42347-y

Cited by

6 publications

Public catalog entries on Sciscape.