A shift based on training labels reduced probability error and kept contact order in a fixed SEEG model tested on 36 patients
A fixed logistic model predicted clinical seizure onset zone labels in public SEEG data from 36 patients at one hospital. Each test patient was absent from training. A constant logit shift based only on the mean training patient label frequency reduced mean Brier score from 0.19723 to 0.07587 and mean log loss from 0.57669 to 0.27371. Within-patient AUC stayed at 0.78385, and every contact order stayed the same. Brier score fell in 35 patients; log loss fell in 34. In 1000 patient draws with model refitting, the central 95 percent interval for the Brier change was -0.13955 to -0.10538. A model trained with natural class fractions had very close mean losses. The result shows lower probability error for this fixed model and contact set. It does not establish exact calibration or clinical benefit. The package preserves code, source powers and labels, all predictions, fit details, draws, four raw signal examples, independent checks, and reproduction instructions.
stereoelectroencephalography · probability calibration · seizure onset zone · logistic regression · class imbalance · Brier score · log loss · patient-held-out evaluation
References
5- usesAdding power variation lowered mean seizure onset ranking AUC in a fixed linear model of two short SEEG records from each of 36 patients sci:sha256:f7d55cf3a83eaf59d975c3549c9ebbbe67d1388cd3d1131b52bbf4b55f67f869
This publication informs the two median-power inputs and the contact position control. The new study fits its own specified mean-loss model and tests probability error, which the earlier ranking study did not assess.
- usesSmaller scaled contact numbers ranked seizure onset labels with mean AUC 0.676 in two short SEEG records for each of 36 patients sci:sha256:9f7fc3dd7992b9fb698f1a4fbde362238501922fcf4ecace3730b64919403c1e
This publication informs the contact position control and the fixed 0.01 slope penalty on weighted mean log loss. Its patient exclusion method also informs the test design.
- usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33
This publication supplies the unchanged 72 SEEG window-power files, clinical labels, fixed 36-patient contact set, source metadata, and pinned raw retrieval records. These inputs support the new probability error audit.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The analysis uses the OpenNeuro ds004100 version 1.1.3 source data, clinical labels, and electrode metadata.
- doi:10.1093/jamia%2Focac093
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.