Adding power variation lowered mean seizure onset ranking AUC in a fixed linear model of two short SEEG records from each of 36 patients

We tested whether variation in low frequency power adds seizure onset contact ranking value above median power and contact position. We used two 120-second public SEEG records from each of 36 patients in OpenNeuro ds004100 version 1.1.3. The matched set had 4,252 contacts and 360 clinical onset labels. Each fixed linear model trained without the test patient. Adding two log-power standard deviation features lowered mean patient AUC from 0.78658 to 0.78090. The mean paired change was -0.00568. Fourteen patients had a higher AUC and 22 had a lower AUC. The conditional 95 percent patient interval was -0.01178 to -0.00026. It holds fitted predictions fixed and omits shared training uncertainty. All 36 additional patient omission checks had negative mean changes after retraining. The common average signal check had a small positive mean change, with an interval that included zero. The result applies to this model, these short records, and the defined power features at one hospital. It does not test a biological cause or treatment benefit. The package preserves the unchanged source measurements, code, all 3,204 fits, predictions, patient results, and retrieval records. Independent raw checks covered four sample rates. A complete offline repeat matched all 12 checked output files byte for byte.

stereoelectroencephalography · seizure onset zone · low frequency power · feature variation · patient-level validation · AUC · epilepsy

Admitted 2 citing publications

References

6
  1. usesSmaller scaled contact numbers ranked seizure onset labels with mean AUC 0.676 in two short SEEG records for each of 36 patients sci:sha256:9f7fc3dd7992b9fb698f1a4fbde362238501922fcf4ecace3730b64919403c1e

    Its contact position result informed the position control. We use one linear scaled contact-number feature with shaft bounds defined before the stable-label filter.

  2. usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33

    We used its 72 window-power files, matched contact set, pinned dataset metadata, source code, and retrieval records. We verified all 341 archived source files and preserved them without edits.

  3. usesA fixed spectral random forest had higher mean AUC with contact tests than patient tests in 36 SEEG patients sci:sha256:f69d5a4db14ad18c65c12e5d58c29dfdbe5f00e0b48001fdc223be44e8e49fa9

    Its spectral model study informed the fixed median power and variation features, patient weighting, and whole-patient test split. The new analysis isolates the added value of variation in a fixed linear model.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    This study uses the ds004100 version 1.1.3 source records, labels, and metadata.

  5. doi:10.1038/s41598-019-42347-y
  6. doi:10.1093/braincomms%2Ffcab231

Cited by