A fixed ridge test did not confirm an EPSP width prediction gain from target time constants in 382 human layer 2–3 connections
We tested whether a target cell's membrane time constant improves prediction of excitatory response halfwidth in human layer 2–3 cortex. A fixed ridge model already used cell type, soma depth, and soma distance. Each test excluded one donor. Penalty selection used only the remaining donors. In the main sample of 382 connections from 18 donors, the added time constant reduced mean donor squared log error by 0.71%. A 95% donor bootstrap range that repeated all fits was −2.82% to +3.54%. The planned signal-to-noise ratio (SNR) check kept responses with SNR at least 3. Its 318 connections from 17 donors gave 7.27% lower error, with a complete-refit range of +0.82% to +13.59%. A larger penalty range and a common donor panel retained this sample contrast. Adding source time constants alone gave no clear gain. A simple passive membrane model also gave no clear direct gain over a training mean. Only 391 of 601 input-eligible connections had an available width. Slow responses and quality review both caused missing widths. These local slice recordings are not a complete anatomical connectome. The selected result does not establish prediction accuracy for unmeasured edges. The package preserves new code, source provenance, row selections, predictions, model fits, bootstrap results, figures, and repeat instructions.
human cortex · synaptic integration · membrane time constant · EPSP halfwidth · donor exclusion · connectome models · signal-to-noise ratio
References
5- usesdoi:10.1038/s41593-025-02134-7
This source study supplies the cell measurements, connection records, electrical types, and definitions of response width and quality review.
- usesdoi:10.6084/m9.figshare.28184126.v1
We analyze the fixed version 1 source tables in file 58515709. The source archive remains external under its stated GPL 3.0+ terms.
- doi:10.1093/cercor/bhac246
This study gives evidence that receptor activation can prolong human excitatory responses. It motivates limits of a membrane-only duration rule.
- A passive current filter gave no clear voltage prediction gain in 197 mouse V1 excitatory connections from Allen r2.1 sci:sha256:8c700a70e37fc5c4a8a4d92530bb5d12eb4e6461c1b761608d9408ac68f1b60a
This related study tests a passive current-to-voltage amplitude rule in another source release. We test response duration with new code and data.
- Time constants gave no clear direction prediction gain beyond type and depth in 539 one-way human temporal cortex pairs sci:sha256:9ebbf70b140d3e88c7ba415d333079a715361852b587920c9553a35a96acddf3
This study tests time constants and connection direction in the same release. Our test concerns response duration.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.