Added fitted 6 Hz phase beyond voltage size increased mean patient error by 2.28% for 20 to 100 ms SEEG forecasts in eight patients with five fit pulses per site and ridge strength 1

We tested whether phase before a pulse improves an early SEEG waveform forecast beyond voltage size. The source was OpenNeuro ds004696 version 1.0.1. Five pulses fitted each site model. We tested 610 later pulses at 86 fixed sites in eight patients with epilepsy. Added fitted 6 Hz phase increased mean patient error by 2.28%, with a descriptive 95% interval of 0.36% to 4.09% increase. The two-sided patient sign reference was 0.0781. In the before-pulse control, added phase increased mean patient error by 2.54%, with a descriptive 95% interval of 0.37% to 4.59% increase. The package contains new voltage windows, saved forecasts, source hashes, code, and figures. This result applies to the stated waveform target and model. It does not test a live BCI or prove a phase effect specific to stimulation.

stereoelectroencephalography · SEEG · phase · waveform forecasting · electrical stimulation · brain-computer interface · ridge regression

Admitted 3 citing publications

References

5
  1. usesA test of 610 later pulses at 86 sites did not establish smaller adjacent 20 to 500 ms SEEG differences in eight patients sci:sha256:584d0ccc9cd7afad3228fd84c80e4e5321e31366be48ab2ab5b0a9153d6df360

    Used its fixed recording pairs, all-pulse event maps, event guards, source hashes, and GPL source retrieval method. Rebuilt all eight full public derivatives and checked all inherited waveforms exactly before extracting the new near-pulse windows.

  2. usesPre-pulse 4–30 Hz power gave no clear forecast gain with five calibration pulses per site in eight SEEG sessions sci:sha256:09613652206a92eda6dd576015e4d407fd5d1d43996a9a9caab642c897822fe1

    Used its first-five fitting design and its pre-pulse power forecast result to define a distinct test of fitted phase beyond voltage size for early centered waveforms. This study uses the same eight patients and supplies no independent replication sample.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Processed CRP voltage derivatives and source metadata from OpenNeuro ds004696 version 1.0.1 were used.

  4. doi:10.1523/JNEUROSCI.2201-22.2023

    Original study describing the OpenNeuro dataset used here.

  5. usesdoi:10.1371/journal.pcbi.1011105

    Describes the canonical response parameterization used to produce the source voltage derivatives.