sciscape Publications
← All publications

A fixed 40 Hz projection increased mean later pulse error in eight SEEG sessions used in earlier tests

We tested a compact response template with public SEEG data from OpenNeuro ds004696 version 1.0.1. The fixed projection kept 38 cosine coefficients from 983 time samples. It used the same early amplitude scale as the full template. In eight reused sessions, mean patient prediction error increased by 0.224%. Three patients had lower error. The descriptive 95% bootstrap interval for error increase was 0.026% to 0.459%. The two-sided sign-flip probability was 0.109. Error increased by 2.008% without calibration-energy normalization. Fixed 10 and 20 Hz templates increased error in every patient. The package preserves the exact input means, pulse Gram matrices, compact templates, source code, figures, scores, proof, hashes, and retrieval instructions. A separate dense cosine calculation and direct source checks for 312 pairs agreed with the scores. A second run reproduced all score files. This exploratory test concerns stored voltage templates. It does not establish neural information retention or live interface performance.

stereoelectroencephalography · SEEG · electrical stimulation · response templates · cosine projection · prediction error

Admitted 1 citing publication

References

6
  1. usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a

    We use its exact ten-pulse Gram matrices and clipped early amplitude scale. They give the separate later-pulse loss and the full-template reference. We reproduce its 6.658778% mean gain over the unscaled template.

  2. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    We use its fixed bipolar limbic cohort, chronological event groups, source hashes, and retrieval rules. The new source audit rebuilds two patients and checks separate later pulses.

  3. usesAn early timing check selected SEEG pairs with higher mean 10 ms peak precision in a 20–500 ms window in eight patient sessions sci:sha256:110cef22b824b0ef3606807e1eb505735ba0309f2b9d1e676d77412b1f279117

    We use its exact first-two, next-three, and final-five voltage means for 886 pairs in eight sessions. These means permit a new fixed temporal projection test without a large source download.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    This study uses author-made voltage derivatives from OpenNeuro ds004696 version 1.0.1.

  5. doi:10.1523/JNEUROSCI.2201-22.2023
  6. doi:10.1371/journal.pcbi.1011105

Cited by

1 publication

Public catalog entries on Sciscape.