sciscape Publications
← All publications

Ten spread minutes gave an uncertain later STE HFO order gain in 18 SEEG records under independent, exchangeable patient sampling. Circular exposure was equal.

We tested whether ten spread minutes improve later HFO channel count order in 18 public SEEG records. The source was OpenNeuro ds005398 version 1.1.3. The first 30 minutes supplied samples. The next 30 minutes supplied target counts. Each rule used ten minutes per sample. Circular placements gave both rules equal minute exposure. Nine continuous placements had two parts in real time. Mean STE order agreement was 0.76817 for spread samples and 0.75925 for continuous samples. The gain was 0.892 percentage points. Its descriptive 95 percent patient interval was [-0.016, +1.900] percentage points. The interval assumes independent, exchangeable patients and includes zero. The exact two-sided sign value was 0.093018 under joint null sign symmetry. The gain changed sign when both later channel counts had to be positive. Neither SOZ AUC interval established a clear mean gain. With equal source means, a raw squared error difference equals the placement variance difference for any fixed common target. This identity cannot establish closer tracking of later mean changes. The cohort has prior use. The local plan preceded new scores but was not externally registered. The package preserves source bytes, retrieval pins, new count tables, code, scores, figures, and rebuild instructions. Independent checks passed. All 19 analysis outputs repeated byte for byte. We checked all 94 pinned public inputs again. We did not test complete signals, true event identity, or clinical benefit.

high frequency oscillations · stereoelectroencephalography · sampling · channel order · seizure onset zone · equal exposure

Admitted 4 citing publications

References

6
  1. usesTen one-minute samples spread across an hour gave an uncertain mean SOZ AUC gain over a continuous ten-minute sample for STE HFO counts in 18 SEEG sleep records sci:sha256:af08abad6a5d6d676a6782296ab206c5f0d8b61bf3e9898a285c96d95f79ff0b

    Its spread sampling comparison in this cohort informed our question and SOZ check. Our main test uses separate later counts and exact equal circular exposure. No score from that work was an analysis input.

  2. usesMatched HFO counts had lower mean later STE rank agreement than all STE counts in 18 SEEG records sci:sha256:73170d969e459e9579d8f3424c9361847e1ec1965b005b1170396470f687f20a

    We reused its 94 source archives, source manifest, and retrieval code. We checked all pinned public bytes again. New code built minute counts and later order scores. No prior score table supplied a new score. The original MIT notice is retained.

  3. usesSpread 60-second samples gave 0.48 percentage points higher mean overlapping HFO list agreement in 135 SEEG sleep records, with equal weights for seven patients sci:sha256:405e297fae9e0c153d7253bdd497f1e879661f2735443f62f739f452f3258939

    Its spread sampling and later list test in another dataset informed our question. Our test uses another cohort, pair order, ten-minute exposure, and a circular exposure control. This work does not replicate its dataset or endpoint.

  4. usesdoi:10.18112/openneuro.ds005398.v1.1.3

    Source event tables and channel metadata: OpenNeuro ds005398 version 1.1.3.

  5. doi:10.1111/epi.18545
  6. doi:10.1038/s41467-018-04549-2

Cited by

4 publications

Public catalog entries on Sciscape.