sciscape Publications
← All publications

Ten one-minute samples spread across an hour gave an uncertain mean SOZ AUC gain over a continuous ten-minute sample for STE HFO counts in 18 SEEG sleep records

We tested ten minutes of analyzed time in the first hour of 18 public SEEG sleep records. One rule used a continuous sample. The other used ten one-minute parts spread across the hour. Each rule had six fixed placements with equal total time coverage. The primary scores used released STE HFO counts and clinical SOZ channel labels. Mean AUC was 0.70699 for continuous samples and 0.70932 for distributed samples. The patient mean gain was 0.00233. Its 95% patient bootstrap interval was -0.00358 to 0.00840. The exact patient sign-flip test gave p = 0.47172 under independent patients and symmetric signs. The data do not establish a positive population mean gain or equal performance. A secondary result gave a placement SD reduction of 0.01408, with a patient interval of 0.00033 to 0.02960. A separate reference under exchangeable minute order gave a Holm-adjusted conditional value of 0.003 for this reduction. Five of six planned checks left the SD reduction uncertain. This is a secondary analysis of one existing cohort. It does not test a neural cause or treatment benefit. The package preserves source tables, pinned retrieval recipes, hashes, code, all scores and random draws, a reference proof, figures, and repeat instructions. All 94 public reader inputs matched their hashes. Separate calculations checked every placement score and every minute order draw. A full repeat gave identical numerical files.

high frequency oscillations · stereoelectroencephalography · seizure onset zone · sampling · area under the curve · intracranial EEG

Admitted 7 citing publications

References

5
  1. uses20 ms detector matches gave an uncertain SOZ rank gain over combined counts in the first hour of 18 SEEG sleep records sci:sha256:e2fb21fc2b8904e6e332f4adef0382d28035541049ea83d70d8da9f15b9adbb1

    This publication supplied the source event archive, pinned source manifest, eight reader and rank functions, and retrieval code. We used these inputs for a new equal-exposure sampling test with SOZ labels.

  2. usesSpread 60-second samples gave 0.48 percentage points higher mean overlapping HFO list agreement in 135 SEEG sleep records, with equal weights for seven patients sci:sha256:405e297fae9e0c153d7253bdd497f1e879661f2735443f62f739f452f3258939

    This earlier study tested distributed HFO samples with equal time coverage and a minute order reference in another dataset. It supplied context for the sampling question. The present test uses clinical SOZ labels in ds005398.

  3. usesdoi:10.18112/openneuro.ds005398.v1.1.3

    Source dataset version 1.1.3 supplied the event marks, channel labels, participant metadata, and EDF headers analyzed here.

  4. doi:10.1111/epi.18545
  5. doi:10.1038/s41467-018-04549-2

Cited by

7 publications

Public catalog entries on Sciscape.