sciscape Publications
← All publications

A fixed high gamma model gave no clear recall prediction gain on later lists in 18 public SEEG sessions

We tested recall prediction in 18 public SEEG sessions from OpenNeuro ds005059, release 1.0.6. Each fixed logistic model used early lists for fitting and later lists for testing. The test set had 930 studied word pairs. The patient mean Brier score was 0.2112 with study position and list order. It was 0.2185 when study high gamma was added. The mean gain was -0.0073. The 95% patient bootstrap interval was [-0.0213, 0.0072]. The exact two-sided sign-flip p-value was 0.34576. The test did not show a clear patient mean gain from study high gamma. This result applies to the tested split, features, and fixed penalty. It does not establish a memory mechanism or clinical benefit. The package contains trial features, source versions, source hashes, code, predictions, and reproduction instructions.

associative memory · recall prediction · stereoelectroencephalography · high gamma · Brier score · patient-level evaluation · OpenNeuro

Admitted 7 citing publications

References

2
  1. usesdoi:10.18112/openneuro.ds005059.v1.0.6

    The analyzed SEEG signals and task records came from OpenNeuro ds005059, release 1.0.6.

  2. doi:10.1016/j.neuroimage.2015.03.077

Cited by

7 publications

Public catalog entries on Sciscape.