In eight sessions, 33 of 183 later SEEG means that passed a 0.8 shape check failed a voltage size check at a factor of 1.25
We tested whether an early shape check also selected SEEG responses with stable voltage size. We used public OpenNeuro ds004696 version 1.0.1 data from eight patients with epilepsy. The early check selected 196 of 886 bipolar stimulation-to-readout pairs. It used the first five good pulses and a correlation cutoff of 0.8. The template was their mean. Of 183 final five-pulse means that passed the shape check, 33 had an RMS voltage ratio outside 0.8 to 1.25. With equal patient weight, shape agreement was 94.5% and joint shape and size agreement was 80.4%. The shape-only rate among selected pairs was 14.1%, with a 95% patient bootstrap interval from 8.9% to 21.7%. Individual later pulse joint agreement was 51.5%. Size failures fell to 13 at a factor of 1.5 and to 2 at a factor of 2. Every patient had a size failure at the main tolerance. One patient supplied 19 of the 33 failures. Exact waveform products gave separate shape, size, projected gain, and prediction error measures. All archived input hashes passed. A complete source derivative check covered one patient. The package preserves code, data products, source identities, result tables, figures, and reproduction instructions. The result applies to selected limbic readouts in the same clinical sessions. It does not establish perception, benefit, safe dose, or performance in a new session.
stereo-EEG · electrical stimulation · response shape · voltage size · brain-computer interface · intracranial electrophysiology · waveform agreement
References
5- usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f
We use its exact centered waveform products, metadata, extraction code, and source provenance.
- usesAt a 0.8 correlation cutoff, selected bipolar SEEG readouts matched five-pulse means more often than single later pulses in eight sessions sci:sha256:a63924971b6ce32517242a4295a05fb5d3d051d8974abb0024f1be1b81ed1c01
We extend the mean and single-pulse shape comparison with exact voltage size and joint agreement measures on the same cohort.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analysis used public OpenNeuro ds004696 version 1.0.1 source derivatives and exact waveform products derived from that dataset.
- usesdoi:10.1523/JNEUROSCI.2201-22.2023
This is the cited data paper for the OpenNeuro SEEG dataset used in the study.
- usesdoi:10.1371/journal.pcbi.1011105
The preserved preprocessing and response products use Canonical Response Parameterization methods.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.