Selected SEEG pairs had mean patient agreement of 75% within 10 ms for 20–100 ms peaks in five patients
We tested absolute peak time in public SEEG data from five patients. We selected the top 10% of site-to-contact pairs by response energy in five pulses. We tested these pairs with the other five pulses. We used all 252 oriented five-of-ten subsets. The search range was 20–100 ms. A peak was the largest absolute voltage after removal of the before-pulse mean. Mean patient agreement within 10 ms was 74.9% after the pulse and 22.2% before it. The mean patient fraction with either after-pulse peak at a search limit was 47.8%. Each patient had a positive after-minus-before effect. The exact two-sided patient sign-flip p value was 0.0625. This test assumes independent patients and symmetric null effects. The observed timing agreement depends on the search range and voltage-centering rule. The data cannot measure responses before about 21 ms or establish conduction delay. The package contains derived data, source hashes, a raw retrieval recipe, code, full results, and checks.
SEEG · stereoelectroencephalography · peak time · evoked response · electrical stimulation · intracranial EEG · reproducibility · patient-level analysis
References
4- usesSEEG pairs selected with five pulses had a mean rank AUC of 0.961 on five unused pulses in five patients sci:sha256:4cb93b4374dae5c9400231a8d61957259ba179017f9913a484a8b6e0c47edd96
This publication supplies the five derived voltage arrays, receiver choices, and source locks. We used these inputs to test peak time agreement with separate pulse groups.
- usesFour shared pulses increased correlation between five pulse SEEG averages in five patients sci:sha256:b32094dc7392cb00836046de174e97c74b5e22bff748e10cb681317ecbf47b6d
This publication supplies the original pulse-window extraction and its provenance. We rebuilt these windows from the source recordings and used them for a new peak time analysis.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
This is the exact OpenNeuro ds004457 version used for the source recordings.
- usesdoi:10.1523/JNEUROSCI.1325-22.2023
This paper describes the source recordings and their collection context.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesPeak amplitude scores had a higher mean AUC than peak isolation scores for late peak time agreement in five SEEG patients
This report was read after the main analysis. It supplies related context on the effect of search windows and the same constant source pulse. Its endpoint differs from the score AUC tested here. It did not supply the main analysis input or change the fixed plan.