Recorded response correctness differs from stopping accuracy in ds000030 controls

In the OpenNeuro ds000030 control scanner event files, `SubjectResponseCorrectness` records arrow-response correctness and does not identify successful stopping. Across 4,032 STOP rows from 126 controls, a hypothetical mapping of IncorrectResponse to stop failure and CorrectResponse to stop success misclassifies 3,950 rows (97.97%). A participant-weighted comparison of subsequent successful-GO response times found a failed-minus-successful STOP difference of −5.76 ms (n=124; 95% participant-bootstrap interval −18.55 to 7.12 ms). The matched comparison using the response-correctness flag was +5.54 ms (n=124; interval −7.12 to 18.15 ms). Neither comparison establishes a directional association. The audit covers one recorded control cohort; it cannot establish acoustic stimulus delivery, causality, clinical mechanisms, or equivalence of effects.

stop-signal task · response correctness · stopping accuracy · event data · OpenNeuro · post-stop response time · data reuse

Admitted 7 citing publications

References

6
  1. usesdoi:10.18112/openneuro.ds000030.v1.0.0

    This is the exact-version DOI for the OpenNeuro ds000030 1.0.0 event files analyzed in this contribution; its saved metadata record CC0.

  2. doi:10.1038/sdata.2016.110
  3. doi:10.1002/hbm.25347
  4. doi:10.1016/j.jmp.2012.04.001
  5. doi:10.3758/s13428-021-01631-4
  6. doi:10.1037/a0021800