sciscape Publications
← All publications

Removing the half of selected sites with the highest fitting reliability decreased sound assignment accuracy more than random removal in six SEEG patients and two fMRI panels

We tested whether repeat reliability on one sound set marks sites useful for reading other sounds. Separate public studies supplied human SEEG high-gamma responses and BOLD fMRI estimates. Two sound folds kept fitting sounds out of each test. We removed half the sites with the greatest fitting reliability. We compared the retained sites with 32 random sets at the same site count. Each response lost its spatial mean, size and global sign. Development used two patients and four MRI adults. Before reserved tests, we added labelled accuracy loss to two original site-label benefit tests. A local code lock preceded tests in six patients, 16 B2021 adult records and eight NH2015 adult records. Added accuracy losses were SEEG +19.81 points; B2021 +12.25 points; NH2015 +8.22 points. The accuracy-loss shared test passed, with Holm p=0.046875 over three claims. H1 and H2 did not pass their shared tests. All records, negative outcomes, code, figures and uncertainty draws remain. Original neural arrays stay external. SEEG pre-onset loss was +4.08 points; baseline subtraction left +12.66 points. Thus the result does not isolate sound-evoked coding. Source screens used the full sound panel before release. Separate cohorts, possible overlap between MRI panels, clinical sampling, shared schedules and signal mixing limit scope. The tests concern fixed processed-signal readers. They do not establish neural necessity, source count or causality.

human neuroscience · SEEG · fMRI · auditory cortex · repeat reliability · site removal · sound patterns

Admitted 5 citing publications

References

11
  1. usesKeeping site labels improved repeated sound assignment after mean, size and global sign removal in six SEEG patients and 24 fMRI adults sci:sha256:3de43695aee9eba4e9670d283d540979dc41511aa5e3443dfcc5d67325a68e7f

    We reuse source pins, source-format readers and pattern reader arithmetic. We add disjoint-sound reliability ranks, half-site removal and a three-claim held-out test.

  2. At selected auditory sites, the top quarter by voice preference retained tuning in a source nonvocal panel in six SEEG patients and 24 fMRI adults sci:sha256:6c152eb830bf619a15a82d19da0ee61036689d52aa8fe5a14201c9ee7ab07470

    Prior selected-site tuning test; it differs from reliability-ranked removal.

  3. Two fixed voice detail tests failed their shared rule in six SEEG patients and 24 fMRI adults sci:sha256:6a6ca6a9f2b860488aff637c6a6a22a497d79cc900757f0f36a02979b42f7f9d

    Prior failed voice-detail tests informed the scope and the need to retain negative outcomes.

  4. doi:10.1126/science.1063736
  5. doi:10.1016/j.cub.2009.01.066
  6. doi:10.1371/journal.pbio.3001675
  7. doi:10.5281/zenodo.6544488
  8. doi:10.1152/jn.00588.2020
  9. doi:10.1371/journal.pbio.3002366
  10. doi:10.5281/zenodo.8349726
  11. doi:10.1016/j.neuron.2015.11.035

Cited by

5 publications

Public catalog entries on Sciscape.