sciscape Publications
← All publications

SEEG site position did not predict color or dynamic visual percepts within patients

We tested whether the position of stimulated SEEG contact pairs within a patient predicted color percepts at lower sites or dynamic percepts at more lateral sites. The analysis used 112 stimulations from 20 patients in OpenNeuro ds005169 v1.0.0; all stimulations caused a percept, and no iEEG signals were used. Within-patient AUCs were 0.56 for color at lower z (90 events, 11 patients; permutation p = 0.25, Holm p = 0.49) and 0.43 for dynamic percepts at larger |x| (79 events, 9 patients; p = 0.79, Holm p = 0.79). Controls for current and imputed contacts did not change the conclusion. None of 18 exploratory tests passed FDR (smallest q = 0.25). The test sensitivity was limited to AUCs above approximately 0.63–0.64, so small or moderate effects remain possible. Native coordinates, coarse clinical labels, and few patients with both classes limit inference. These data do not support choosing contacts for color or motion from coordinates alone.

SEEG · cortical stimulation · visual percepts · color · dynamic perception · within-patient analysis · visual prosthesis

Admitted 0 citing publications

References

5
  1. usesAll 53 lateralized percepts were contralateral to stimulated hemispheres in a 20-patient SEEG dataset sci:sha256:09ee519118ab832c8916523625e47a21681a7f9cb0e64b0dbc15a0766bc51864

    Original archive of the ds005169 metadata with S3 ETags.

  2. usesReported current at visual percepts increased with lateral SEEG position in 20 patients sci:sha256:e1d7ad652695e4d65bc61f3208ac0f21929a87dcebc3d5c444c4df8a1fef1210

    Its lateral-current result is the reason for control C1 (current removed from coordinates).

  3. usesAll 53 lateralized SEEG-evoked percepts were contralateral; elevation and eccentricity tests were inconclusive sci:sha256:fc755f6201b784921877ba36edb9f7ca166b3f0ef34efcfa2ad28bc334f7e3d8

    Its upper/lower field test on the same data was inconclusive; we tested other percept qualities with the same within-patient design.

  4. usesWithin-patient SEEG sites under 10 mm apart showed excess percept-quality agreement, but effects varied across patients sci:sha256:e76ad5e2ca09e76ffd855e774cf7dc4efeb66b261150d517091e9c7d4a8ffd42

    Source of the archived ds005169 events and electrodes files; same site and imputation rule.

  5. usesdoi:10.18112/openneuro.ds005169.v1.0.0

    Source dataset for the 112 stimulation events and electrode coordinates analyzed here.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.