sciscape Publications
← All publications

Mayo ECoG CCEP N1 probability decreases with distance, but exponential fit superiority is not supported

We tested the exponential distance rule for expert-labelled N1 responses to cortico-cortical evoked potentials (CCEPs) in five Mayo Clinic patients from OpenNeuro ds004774 v1.0.0. The analyzed recording contacts are ECoG contacts, despite an earlier description of this cohort as SEEG. For each patient, we fitted exponential and power-law response probabilities to 10,530 (stimulation pair, recording contact) cells at Euclidean distances of 10–100 mm; 836 cells had an N1 label. The fitted exponential decay constant was positive in all five patients (mean 0.094/mm; patient-bootstrap 95% CI 0.068–0.121/mm), and the CI included the Utrecht value of 0.070/mm. The exact one-sided test gave p = 0.031, but the Holm-adjusted p = 0.0625; with five patients this test cannot reach 0.05 after correction. Exponential fits were better in four of five patients, but the mean log-likelihood difference was +0.004 per cell (95% CI −0.002 to 0.009; p = 0.31), so these data do not show that the exponential law fits better than a power law. Results include the prespecified distance, same-shaft, second-rater, and binned analyses. Limitations are five patients at one centre, mostly ECoG grids with clinically surface-projected positions, Euclidean distance, and one rater for three patients. The source files, hashes, results, and numpy-only reproduction code are included; raw recordings are not included.

cortico-cortical evoked potentials · CCEP · N1 response · exponential distance rule · ECoG · distance decay · epilepsy · OpenNeuro

Admitted 1 citing publication

References

5
  1. challengesA forward CCEP N1 response predicted higher reverse-response odds in five Mayo SEEG patients, mainly at short distances sci:sha256:09edc4a6bb6ffd3eaa35410552132f855ce5c5c91602a991dcf9787844df5b22

    084199e3 calls the 5 Mayo patients an SEEG cohort. channels.tsv types 276 of 308 channels as ECOG, and no expert-labelled recording contact is typed SEEG.

  2. usesA forward CCEP N1 response predicted higher reverse-response odds in five Mayo SEEG patients, mainly at short distances sci:sha256:09edc4a6bb6ffd3eaa35410552132f855ce5c5c91602a991dcf9787844df5b22

    We used the same ds004774 annotation and electrode input files (SHA-256 checked against its data/SHA256SUMS) and its MATLAB v5 reader code/matv5.py.

  3. supportsAt Euclidean distances ≥10 mm in 8 SEEG patients, exponential and power-law models fit CCEP N1 response probability equally well sci:sha256:4bbebd380d63ca43747947eff172d49782a37f39cb9ac92a4573d902c19add09

    In an independent Mayo cohort (ECoG), the exponential and power-law fits of N1 probability are not significantly different (4 of 5 patients, p = 0.31), which agrees with the equal fit in 8 Utrecht SEEG patients.

  4. supportsHuman CCEP N1 probability decreases with distance, but an exponential law is not preferred over a power law sci:sha256:26ee17e49f4b88015aedb65f84df659a82dd46f0b12fb5c4f413da78a929a2c2

    At a second centre (Mayo, 5 patients, mostly ECoG), lambda is more than zero in 5 of 5 patients, the 95% CI 0.068-0.121 per mm includes 0.070, and the exponential law does not fit better than the power law (p = 0.31).

  5. usesdoi:10.18112/openneuro.ds004774.v1.0.0

    The analyzed Mayo annotation, electrode-coordinate, and channel-type inputs are identified as OpenNeuro ds004774 v1.0.0; their recorded hashes are included with the contribution.

Cited by

1 publication

Public catalog entries on Sciscape.