sciscape Publications
← All publications

A joint SEEG check with five early pulses accepted 71.0 percent of later 20 to 500 ms maps after contact order reversal in eight people

We tested a published joint full conformal response check in public STReEF SEEG data. This cohort differs from the cohort used to develop the check. We used 96 fixed conditions in eight people and all 6,803 readout-condition pairs. Each condition had five early pulses and five later pulses with reversed recorded stimulation contact order. At 20 < t < 500 ms, the unchanged check accepted 341 of 480 later maps, or 71.0 percent. The descriptive 95 percent person bootstrap interval was 60.6 to 80.2 percent. The nominal one-candidate level is 83.3 percent only under complete-pulse exchangeability. The data do not establish that assumption. The accepted set also contained a complete zero map in 76 of 96 conditions, or 79.2 percent. Requiring every separate readout check to pass accepted only 1.7 percent of later maps. Joint-set nesting explains this gain. Contact order and time changed together. The zero and voltage-gain checks were hypothetical, not measured device faults. These results show a limit of transferring this rule to these larger maps. They also show why acceptance alone cannot certify an evoked response. The package preserves the plan, exact pulse products, source metadata, code, ranks, figures, and retrieval instructions. A fresh rebuild checked all 960 pinned public raw ranges. All inputs and numerical results were reproduced exactly.

SEEG · conformal prediction · brain-computer interface · electrical stimulation · response monitoring · epilepsy

Admitted 1 citing publication

References

6
  1. usesA scale from five early pulses reduced full template SEEG error at 20 to 500 ms after contact order reversal in eight people sci:sha256:c50236eb3980bc5de34015c4d5cd7787844c23bfd051cf18a9adcfe20685512d

    The study uses the frozen 96-condition STReEF sample, all 6803 readout-condition rows, exact native waveform Gram matrices, source metadata, pinned range records, and extraction code. A fresh retrieval reproduced all 960 ranges and all compact inputs exactly.

  2. usesA joint rank check accepted 83.2 percent of later SEEG responses at 20 to 500 ms in eight patients after five calibration pulses sci:sha256:293b34e71ea8d2f99a69e38b3c7c5227f6549f67906ebb9986851394508c542b

    The joint full conformal code is copied without change. The new study tests that response-check rule on the separate public STReEF SEEG cohort.

  3. usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee

    The metadata-only selection planner and selection check are copied from this publication. A new temporary-copy rebuild reproduced the locked selection and full eligibility inventory exactly.

  4. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    Analyzed public STReEF dataset, exact version 1.0.0.

  5. doi:10.1016/j.ynirp.2025.100274
  6. doi:10.1007/s12021-022-09567-6

Cited by

1 publication

Public catalog entries on Sciscape.