sciscape Publications
← All publications

Signed templates had mean AUC 0.7925 versus 0.83625 for energy at 20–500 ms after contact order reversal in eight SEEG sessions

A five-pulse signed waveform template was compared with voltage energy in public STReEF data, OpenNeuro ds005448 v1.0.0. The fixed sample had eight SEEG people and 96 stimulation conditions. One readout per condition was selected from early pulse energies. Both scores used that readout. Five later pulses followed recorded contact order reversal. At 20–500 ms, the equal person mean AUC was 0.79250 for the signed template and 0.83625 for energy. The difference was -4.38 percentage points. The exact two-sided person sign-flip test gave p = 0.421875. A descriptive 95% person bootstrap interval was -12.88 to +1.71 points. The data did not establish a general score difference. Absolute projection had mean AUC 0.82958. The signed-minus-energy contrast was -1.58 points at 100–500 ms. The package preserves selected native voltage, all early candidate energies, pulse scores, four figures, code, source hashes, and replay instructions. All 960 source byte ranges were retrieved and checked. Contact order and time are confounded. Eligibility uses later artifact annotations. These results measure sampled pulse-window separation. They do not certify neural response, continuous detection, or live interface benefit.

stereo-electroencephalography · intracranial EEG · electrical stimulation · waveform template · voltage energy · AUC · signal processing · STReEF

Admitted 0 citing publications

References

8
  1. usesA scale from five early pulses reduced full template SEEG error at 20 to 500 ms after contact order reversal in eight people sci:sha256:c50236eb3980bc5de34015c4d5cd7787844c23bfd051cf18a9adcfe20685512d

    The source byte-range extraction code is reused through the cited parent archive. A small change returns all candidate native voltage differences. The source hash checks, channel checks, and voltage scale checks remain in use.

  2. usesA joint SEEG check with five early pulses accepted 71.0 percent of later 20 to 500 ms maps after contact order reversal in eight people sci:sha256:acade5ada72c7dd6c0f618a03497e03a7ceb0afd13274ce9847586c64866b4dc

    This test uses the fixed 96-condition STReEF archive, exact source range receipts, pinned metadata, and early energy values from the parent Gram matrices. Fresh native voltage retrieval checks those receipts. The package reproduces every early readout choice from the parent data.

  3. usesFive-pulse signed templates did not show a clear AUC gain over energy on energy-selected pairs in eight epilepsy SEEG sessions sci:sha256:1406cee5468018906da44ece44823d82527f4a950f45c030e4c2416839f1b976

    The earlier comparison of five-pulse signed templates with energy in ds004696 motivated this transfer test. The current study applies the same type of early energy selection and signed projection to STReEF contact order changes. It adds a separate source result and does not claim a new projection method.

  4. usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee

    The unchanged metadata planner, eligibility rules, and selection check define the eight-person sample and its 6,803 candidate readout-condition rows. The planner and check are included with their source terms.

  5. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The analysis uses the eight SEEG participants and selected stimulation recordings in STReEF, OpenNeuro ds005448 v1.0.0.

  6. doi:10.1016/j.ynirp.2025.100274
  7. doi:10.1007/s12021-022-09567-6
  8. doi:10.1371/journal.pcbi.1011105

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.